Makita HR007G Instruction Manual page 18

Cordless combination hammer
Hide thumbs Also See for HR007G:
Table of Contents

Advertisement

NOTICE:
Never use "rotation with hammering"
when the drill chuck is installed on the tool. The
drill chuck may be damaged.
Also, the drill chuck will come off when reversing the
tool.
NOTICE:
Pressing excessively on the tool will
not speed up the drilling. In fact, this excessive
pressure will only serve to damage the tip of your drill
bit, decrease the tool performance and shorten the
service life of the tool.
Set the action mode changing knob to the
Installing drill chuck set
Optional accessory
Attach the chuck adapter to a keyless drill chuck to
which 1/2"-20 size screw can be installed, and then
install them to the tool. For details on how to install
the adapter into the chuck, refer to the instructions on
installing drill bit.
1
Fig.37
► 1. Keyless drill chuck 2. Chuck adapter
Diamond core drilling
NOTICE:
If performing diamond core drilling
operations using "rotation with hammering"
action, the diamond core bit may be damaged.
When performing diamond core drilling opera-
tions, always set the action mode changing knob to
the
position to use "rotation only" action.
Beating dust on the filter
Optional accessory
CAUTION:
Do not turn the dial on the dust
case while the dust case is removed from the
dust collection system. Doing so may cause dust
inhalation.
CAUTION:
Always switch off the tool when
turning the dial on the dust case. Turning the dial
while the tool is running may result in the loss of
control of the tool.
symbol.
2
By beating the dust on the filter inside the dust case,
you can keep the vacuum efficiency and also reduce the
number of times to dispose of the dust.
Turn the dial on the dust case three times after col-
lecting every 50,000 mm
vacuum performance declined.
NOTE: 50,000 mm
holes of ø10 mm and 65 mm depth.
Fig.38
► 1. Dust case 2. Dial
Disposing of dust
Optional accessory
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
CAUTION:
Be sure to wear dust mask when
disposing of dust.
CAUTION:
Empty the dust case regularly
before the dust case becomes full. Failure to do so
may decrease the dust collection performance and
cause dust inhalation.
CAUTION:
The performance of dust collection
decreases if the filter in the dust case become
clogged. Replace the filter with new one after
approximately 200 times of dust fulfillment as a
guide. Failure to do so may cause dust inhalation.
1.
Remove the dust case while pressing down the
latch lever of the dust case.
Fig.39
► 1. Latch lever
18 ENGLISH
3
of dust or when you feel the
3
of dust equivalents to drilling 10
1
2
1

Advertisement

Table of Contents
loading

Table of Contents