Fault and Handling
Fault Phenomenon
Possible reason
Battery Low
Battery Reverse
LCD no display after
connected with battery
Connection
 The connection cut off
Full of sunshine
The solar panel
vertical on solar
connection open
panel, no solar
circuit, short circuit, or
symbol and no
reverse connected
charging symbol on LCD.
The controller displaying
The
battery
LVD
discharging
The controller displaying
The voltage of battery is
Over Voltage Protection
too high
of battery
The load is short circuit,
The controller displaying
or over load or high surge
Over Current Protection
power
Solution
Please confirm the voltage of
battery
reconnect
controller with battery firmly
and correctly.
Please check the cable
of solar panels if they
are correct connection and
firmly.
Please
check
the
system
is
over
design is reasonable or not.
Please full charge the battery
Please first cut off the solar
panel and see if the voltage
get down normal level. If the
fault do not finish, please cut
off the battery with controller
and reconnect again
Please check the load cables
have short circuit, the power
of the load over rated design,
the surge power of load too
high

Technical Data

Mode
System Voltage
the
PV Max Input Voltage
PV Max Input Power
Self-consumption
Max Charging current
Max Discharging current
LVD
LVR
Float Voltage
Boost Voltage
Battery Over Voltage Protection
Reverse Connection Protection
Load Over Current Protection
Controller
Over
Temperature
Protection
Charging Type
Temperature Compensation
Working Temperature
Terminals scale
Waterproof grade
Size
New weight
* Please under rated power using under high temperature environment.
Optional communication function RS485
Version number:201601
TD2210
TD2410
12V/24V
100V
12V 260W; 24V 520W
12V 520W;24V 1040W
≤23mA
20A
40A
20A
40A
11.0V ADJ 9V....12V;×2/24V
12.6V ADJ 11V....13.5V;×2/24V
13.8V ADJ 13V....15V;×2/24V;
14.4V ; ×2/24battery voltage less than 12.6v restart
boost 2hours
16.5V ;×2/24V
Yes
Yes, each 30s auto restart again
Yes
MPPT
-24 mV /℃ for 12Vsystem ;×2/24V;×4/48V
-20℃---+55℃
2
16mm
IP32
200mm×127 mm×50mm
0.82KG
1.3KG