Protection Function - Ldsolar TD2210 User Manual

Solar charge controller
Table of Contents

Advertisement

supplier suggestion, or unreasonable adjust will destroy battery.

Protection Function

Fault Symbol Indication
State
Symbol
LVD Protection
Battery Over
Voltage
Protection
Load Over
Current
Protection
Controller Over
Temperature
Protection
Solar Panel
Over Voltage
Protection
Short Circuit and Reverse Connected Protection (Solar Panel)
When the solar panels have short circuit or reverse connection, the controller will be
off the charging immediately, after clearing of the short circuit, the charging will be
automatically feedback.
Solar Panel Over Voltage Protection
When the input voltage from solar panel more than 100V, the controller will be off
immediately, after input voltage less than 100V the controller will be auto restart
charging.
Reverse Connection of battery Protection
If the battery reverse connection, the controller will not destroy, corrected the
connection the controller will be normally working.
Battery Over Voltage Protection
When the voltage of battery was more than 16.5V, the controller will be auto closed
charging and output to avoid the damage of the battery and loads.
Condition
Battery empty and Warning
Flash together
Battery full and Warning Flash
together
Load and Warning Flash
together
Temperature symbol and
Warning Flash together
Solar Panel symbol and
Warning Flash together
Battery Type
Over Voltage Protection
Charging Limited
Over Voltage Reconnection
Boost
Float
Boost Restart
Battery Low Voltage Protection (LVD)
When the voltage of battery was reach to LVD (Low Voltage Disconnection) point, the
controller will be auto closed the output in order to avoid over-discharge the battery.
Overload Protection
If the current of load is more than 1.1times rated current of controller, the controller
will be cut off the output after 60s and lock. Users have to decrease loads and press
"→"unlock, or 30s later the controller will auto restart unlock.
Load Short Circuit Protection
When the current of load more than 2times of rated current, the controller will be
confirm short circuit, the controller will be auto cut off the output and lock. Users
have to clearing the short circuit and press"→"unlock, or 30s later the controller will
auto restart unlock
Over Temperature Protection
When the inside temperature of controller was more than 75℃, the controller will be
off the charging and discharging, temperature symbol and warning flash, when the
temperature get down to 65℃, the controller auto feedback.
Lightning Protection
This product could only protect small lightning induction, we suggest users to use
lightning rod at frequency area.
SEL
GEL
FLD
16.5V
16.5 V
16.5 V
15.0 V
15.0 V
15.0 V
15.0 V
15.0 V
15.0 V
14.4 V
14.2 V
14.6 V
13.8 V
13.8 V
13.8 V
12.6V
12.6V
12.6V

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td2410

Table of Contents