Part 1 - Remote Setup
Motion Detection
Select Motion Detection to configure motion detection
event settings. With motion detection event enabled,
motion detections within the designated area will be
assumed as events.
• Sensitivity: Select daytime and nighttime motion
detection sensitivity levels. Higher values will result in
more sensitive motion detection.
• Minimum Blocks for Detection: Select minimum
blocks for daytime and nighttime motion detection.
Motion must take place over the selected number
of blocks in order for it to be considered as a motion
detection event.
• Motion Zone: Click Setup and define the motion
zone using blocks.
(Select)/ (Unselect): Enable/disable motion
-
detection blocks.
(Single Block): Select/unselect motion detection
-
blocks individually.
-
(Zone): Select/unselect multiple motion
detection blocks.
-
(All): Select/unselect all motion detection blocks.
• Motion Ignoring Interval: With Motion Ignoring
Interval configured, no event log or notification is
generated for motions detected during a period of
38
time following a motion detection event.
• Daytime: Specify when daytime starts and ends. All
other times will be assumed as nighttime.
• Event Action: Select a motion detection event alert
action.
- Alarm Out: Select if you wish to generate an alarm
out.
- Send Email: Select if you wish to send an email.
Select the Image Attachment option to attach a
.jpg image of the event detected to the email.
- Remote Callback: Select this option to send a
message to a remote system and then select which
system to send the message to.
• Not supported from the IDIS Web program.
• The camera must be registered to the remote
system in order to use the Remote Callback
feature.
- Audio Alarm: Select this option to generate an
audio alert and then choose an audio file (.wav).
- FTP Upload: Select this option if you wish to
upload images to the FTP server
- Record: Select this option to record video.
- Move PTZ to: Select a preset position to move the
pan/tilt driver to that position. Preset positions can
be set from the remote program.
Event Action settings must be configured correctly
in order to perform event actions.