Electrical Requirements - KitchenAid KICU509XBL Installation Instructions Manual

30" (76.2 cm) and 36" (91.4 cm) electric
Hide thumbs Also See for KICU509XBL:
Table of Contents

Advertisement

Available languages

Available languages

Electrical Requirements

Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
It is not recommended to have a fuse in the neutral or ground
circuit.
Make sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
4
05-Sep-2019 13:08:05 EDT | RELEASED
WARNING
CSA International
In some European factories the letter "W" of the part code mentioned herein will be automatically
Before You Make the Electrical Connection:
To properly install your cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
A 4-wire or 3-wire, single phase, 240 V, 60 Hz, AC only
electrical supply is required on a separate, 40 or 50 A circuit,
fused on both sides of the line.
The cooktop should be connected directly to the junction
box through flexible, armored or nonmetallic sheathed,
copper cable. The flexible, armored cable extending from the
fuse box or circuit breaker box should be connected directly
to the junction box.
Locate the junction box to allow as much slack as possible
between the junction box and the cooktop so that the
cooktop can be moved if servicing becomes necessary in
the future.
Do not cut the conduit. The length of conduit provided is for
serviceability of the cooktop.
A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the
cooktop and at the junction box). A listed conduit connector
is already provided at the cooktop.
If the house has aluminum wiring follow the procedure
below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kicu509xssKicu569xblKicu569xss

Table of Contents