SIZING

Determining dryer capacity at actual operating conditions
To determine the maximum inlet flow capacity of a dryer at various operating conditions, multiply the rated capacity from
Table 1 by the multipliers shown in Table 2.
EXAMPLE: How many scfm can a model 1000 handle when the compressed air to be dried is at 80 psig and 90°F; ambient air
temperature is 80°F; and a 38°F dew point temperature is desired?
ANSWER: 1000 x 1.17 x 1.12 x 1.0 = 1310 scfm.
Pressure Drop
To determine pressure drop at increased flows, multiply the pressure drop at rated conditions from Table 1 by the multiplier
shown in Table 3 for the appropriate air flow rate and operating pressure.
EXAMPLE: What is the pressure drop across a model 1000 when flowing 1500 scfm at 200 psig ?
ANSWER: 1500/1000 = 1.5; multiplier below at 1.5 and 200 psi = 1.1; 1.1 x 4.2 psi = 4.6 psi.
TABLE 1
Rated capacity and Pressure @ 100 psig inlet pressure,
100°F inlet temperature, and 100°F ambient temperature
MODEL
Rated Capacity of
60 Hz
Air-Cooled Models (scfm)
50 Hz
Pressure Drop (psi)
60 Hz
50 Hz
scfm x 0.0286 = m
3
/min
TABLE 2
Air capacity correction factors (multipliers)
INLET COMPRESSED AIR CONDITIONS
INLET
PRESSURES
80°F
psig
kg/cm
2
27°C
50
3.5
1.35
80
5.6
1.50
100
7.0
1.55
125
8.8
1.63
150
10.5
1.70
175
12.3
1.75
200
14.0
1.80
COOLING MEDIUM*
AMBIENT
TEMPERATURE
MULTIPLIER
°F
°C
80
27
1.12
90
32
1.06
100
38
1.00
110
43
0.94
* Air-cooled models; water-cooled models use 1.15 multiplier if cooling
water is below 95°F, 35°C
800
1000
scfm
scfm
800
1000
745
830
3.6
4.2
3.2
3.0
INLET TEMPERATURES
90°F
100°F
110°F
32°C
38°C
43°C
1.05
0.84
0.69
1.17
0.95
0.79
1.23
1.00
0.82
1.31
1.07
0.91
1.37
1.13
0.95
1.42
1.18
0.99
1.47
1.22
1.03
OUTLET DEWPOINT
DEW POINT
TEMPERATURE
MULTIPLIER
°F
°C
38
3
40
4
45
7
50
10
1200
1600
2000
scfm
scfm
scfm
1200
1600
2000
1000
1330
1660
4.1
3.9
4.7
2.9
2.8
3.4
TABLE 3
Pressure drop correction factors (multipliers)
AIR FLOW
120°F
2.0 x rated flow
49°C
1.5 x rated flow
0.56
1.2 x rated flow
0.66
0.70
0.74
0.80
0.84
0.89
1.0
1.1
1.2
1.3
2300
scfm
2300
1910
5.0
3.6
OPERATING PRESSURE psig / kg/cm
60 / 4.2
100 / 7 180 / 12.6 200 / 14.0
5.4
3.5
2.1
3.2
2.1
1.2
2.1
1.4
0.8
2
1.9
1.1
0.7
9