Reference; Sizing - Gardner Denver SPX FLOW DHP Series Instruction Manual

High pressure refrigerated type compressed air dryer
Table of Contents

Advertisement

5.0 REFERENCE

5.1 Sizing

Determining dryer capacity at actual operating conditions
To determine the maximum inlet flow capacity of a dryer at vari-
ous operating conditions, multiply the rated capacity from Table
1 by the multipliers shown in Table 2.
Example: How many scfm can an air-cooled model DHP300
handle when compressed air to be dried is at 350 psig and
90°F; ambient air temperature is 80°F?
Answer: 300 x 1.19 x 1.12 = 400 scfm.
Table 1. Rated Capacity
Rated capacity (scfm) @ 725 psig inlet pressure, 100°F inlet
temperature, and 100°F ambient temperature and 60 Hertz
operation.
RATED FLOW
MODEL
(scfm)
m
DHP130
130
DHP200
200
DHP300
300
DHP500
500
DHP750
750
DHP1000
1000
Table 2. Capacity Adjustment Factors for Air Inlet
Temperature and Pressure
INLET PRESSURES
80°F
(psig)
(barg)
27°C
300 to 725
21 to 50
1.49
Table 3. Capacity Adjustment Factors for Ambient Air
Temperature
AMBIENT
CAPACITY
TEMPERATURE
ADJUSTMENT
°F (°C)
FACTOR
80°F (27°C)
1.12
90°F (32°C)
1.06
100°F (38°C)
1.00
110°F (43°C)
0.94
Water-cooled
(85°F, 29.4°C
1.15
cooling water)
Table 4. Capacity Adjustment Factors for Electrical
Frequency
50 Hertz
60 Hertz
0.83
1.00
8
/hr
3
221
340
510
850
1275
1700
INLET TEMPERATURES
90°F
100°F
110°F
32°C
38°C
43°C
1.19
1.00
0.83
120°F
49°C
0.72