Tally Dascom DL-210
Black mark sensor must be covered by label
rather than label gap. Otherwise, the contents may
exceed label area.
(11) In order to make sure the data is printed within the label area, it is necessary to execute
Label Calibration: Hold down Feed Key and switch on printer simultaneously, release Feed
Key after the buzzer beeps twice. Then the label will be positioned automatically.
Label calibration should be executed in the following situations:
Use printer for printing label first time.
•
Replace different size of labels.
•
Printer skips labels
•
Printer feeds blank labels.
•
(6) Lead the media under the print head
mechanism through the media guides.
(7) Control the blue media guide adjustor so as
to align the media in the central path.
(8) Lead the media over the platen roller and
through the tear bar.
(9) Put the print head mechanism down and
press down firmly until you hear a snap.
(10) Close the top cover and turn on the
printer or press the "FEED" button if the
printer is already on.