Supra CHLOE Installation Instructions And User Manual page 15

Wood burning stove
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10
FUEL
Wood
This high-performance appliance requires good quality fuel. Only
burn air-dried logs (2 to 3 years stored in a sheltered and well-
ventilated place) with a maximum humidity of 15 to 20%.
Preferably hardwoods (birch, hornbeam, beech, etc.).
Avoid softwoods (lime, chestnut, willow, poplar),
It is strictly forbidden to permanently use resinous wood (pine,
fir...) as well as the use of waste from processed wood (railway
sleepers, woodworking waste, etc.) and household scraps
(vegetables or plastics).
Never use small wood, boxes, woodchips and vine shoots as
these will lead to sudden overheating.
TAKE NOTE:
The use of coal or its derivatives is strictly
prohibited, even on an occasional basis. This appliance must
not be used to burn domestic waste.
CONTROLS
Combustion air control
The air control regulates the combustion air flow and permits the
precise control of the fire.
TABLE (*)
Lever
primary air
Lighting the
Open / pulled
fire
out
Nominal
1/2
efficiency
Performance
1/2
in slumber
mode
(The controls for the Chloe stove are shown)
Primary air
pulled out =
open
The door opening
To open-close the door:
- When the appliance is cold, directly with your hands
- When the appliance is hot, with an insulating glove.
LIGHTING THE FIRE FOR THE FIRST TIME
Remove the self-adhesive labels, any possible blocking cards, and
make sure that the ash tray is empty.
The first lighting of the fire and the measurement of the draught
can be performed by a qualified professional.
Start with a small fire and gradually increase the load. This
progressive heating allows the materials to expand slowly and to
stabilise. There may be some fumes and odours, due to the
paintwork. These will gradually disappear. Do this for a few days
until normal use. Open the windows during the first hours of
operation.
SERVICE
Lighting the fire
To light your appliance, preferably use the top down method.This
fire lighting technique makes it possible to heat up the flue and to
remove any blockages (negative pressure) that may form when
the weather is bad or cold, thereby preventing the air from blowing
back into the room when the fire is lit.
STOVE CONTROLS
secondary air
Open / pulled out
1/2
Closed / pushed
in
Secondary air
pulled out =
open
The procedure is as follows:
- Put the air combustion control to the maximum setting.
- Place 2 logs on the firebox grid.
- Place the kindling wood in the shape of a tower on top of the
logs.
- Put 1 or 2 fire-lighter cubes on the wood and set alight.
- Lose the door.
For further information, view the Supra video on YouTube at:
https://www.youtube.com/watch?v=ebOr4vMj2Jo
TAKE NOTE: Never use petrol, alcohol or fuel-oil, etc.
Reloading
Reload the appliance once there is a good bed of embers and the
flames have gone out. Gently open the loading door, to prevent
fumes from getting out (if opening during the combustion stage) or
embers from falling. Once the wood has been loaded, close the
door.
WARNING! The door closes automatically!
Nominal efficiency
Adjust the controls according to the table (*). The intensity of the
fire will be determined by the amount of fuel. The correct operation
of the appliance depends on a suitable air supply.
Chloe stove open (with no combustion air connection)
NOMINAL LOADING
For the optimum operation, load 2 small logs of wood (approx. 2,1
kg/h). Place the logs to the back of the appliance to prevent
embers from falling out.
Performance in slumber mode
Adjust the controls according to the table (*)
Do not operate the appliance in slumber mode for long periods of
time. The temperature of the combustion gases is insufficient and,
instead of being eliminated, they condense in the flue pipe. This
increases the amount of dirt in the chimney and appliance (walls
and glass).
IN THE EVENT OF AN INCIDENT
In the event of an incident in the room (fire in the chimney, fire in
the room, etc.), quickly close the loading door and all the stove
controls. Do not pour water into the firebox. Call the fire brigade.