L max with Ø 80 mm pipe
L max with Ø 100 mm pipe
Ensure that there is no risk of blocking the supply of combustion
air.
On the outside, the air inlet duct must be oriented towards the
prevailing winds. A grid should be installed over the duct opening
to prevent obstructions, with a free cross-section that is the same
as that of the duct and with a mesh of more than 3 mm.
Stove outdoor air connection:
Chloe pedestal - Stove outdoor air connection:
Chloe stove:
A. Rear air connection
1.
Open the stove hatch.
2.
Carefully cut out the rear blanking plate (*) so that there
is no damage to the paint.
3.
Connect the outdoor air inlet collar (with a flexible
aluminium hose - not supplied) with a clamp (not supplied).
4.
Insert the hose in the rear panel.
5.
Close the stove hatch.
B. Lower air connection
1.
Open the stove hatch.
2.
Connect the outdoor air inlet collar (with a flexible
aluminium hose - not supplied) with a clamp (not supplied).
3.
Close the stove hatch.
Chloe stove open
6 m
8 m
*
Chloe stove open
Air connection collar (Ø 80
duct not supplied)
Chloe pedestal:
1.
Connect the outdoor air inlet collar (with a flexible
aluminium hose - not supplied) with a clamp (not supplied).
Air connection collar (Ø 80
duct not supplied)
3. USE
TAKE NOTE:
- This wood burning stove is designed to be used with the door
closed. The door must remain closed except for refuelling.
- To avoid burns, do not touch the appliance and wear insulating gloves
to operate the controls.
- The heat emitted through the vitroceramic glass makes it
necessary to maintain a safety clearance with any material that
could be damaged by the heat (furniture, wallpaper, woodwork,
etc.). A 2 m clearance will avoid any risk.