FSA GT1-20LS Manual

FSA GT1-20LS Manual

Semi commercial reverse osmosis water filter system

Advertisement

Quick Links

Technical Overview ...................................................................................................................................... 2
I. Important Notes ..................................................................................................................................... 2
II. Before You Purchase/Open .................................................................................................................. 2
III. Space Requirements ............................................................................................................................ 2
IV. Before You Begin Installation ............................................................................................................... 3
V. What is Reverse Osmosis ..................................................................................................................... 3
VI. Example Applications .......................................................................................................................... 3
VII. Installation with other Systems ............................................................................................................ 3
Installation Introduction ................................................................................................................................. 4
I. Site Preparation ..................................................................................................................................... 4
II. Installation - Mounting .......................................................................................................................... 4
III. Installation - Free-Standing ................................................................................................................. 4
IV. Installing Connections - Quick Connect ............................................................................................... 4
V. Filter Protection .................................................................................................................................... 5
VI. Drain/Waste ......................................................................................................................................... 5
VII. Cartridge Installation ........................................................................................................................... 5
(a) Pre-Filters ........................................................................................................................................ 5
(b) Membrane ........................................................................................................................................ 5
(c) Post Filters ....................................................................................................................................... 6
(d) De Ionising Post Filters .................................................................................................................... 6
Connecting the System................................................................................................................................. 6
I. Tubing .................................................................................................................................................... 6
II. Power.................................................................................................................................................... 6
Start Up & Operation .................................................................................................................................... 6
I. Commissioning ...................................................................................................................................... 6
II. General Operation ............................................................................................................................. 6
III. Automation ........................................................................................................................................... 7
Maintenance ................................................................................................................................................. 7
I. Replacement Parts................................................................................................................................. 7
II. Replacement Cartridges ....................................................................................................................... 7
III. Parts List .............................................................................................................................................. 8
Troubleshooting ............................................................................................................................................ 8
Semi Commercial Reverse
Osmosis Water Filter System
35L/Hr - GT1-20LS
Contents

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GT1-20LS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for FSA GT1-20LS

  • Page 1: Table Of Contents

    Semi Commercial Reverse Osmosis Water Filter System 35L/Hr – GT1-20LS Contents Technical Overview ............................2 I. Important Notes ............................. 2 II. Before You Purchase/Open ........................2 III. Space Requirements ..........................2 IV. Before You Begin Installation ....................... 3 V. What is Reverse Osmosis ........................3 VI.
  • Page 2: Technical Overview

    Technical Overview I. Important Notes For correct operation of this appliance, it is essential to observe the manufacturer’s instructions. If this system is to be installed permanently as a POU or POE system, installation must be carried out by a qualified plumber or authorised technician to comply with Australian Plumbing Codes.
  • Page 3: Before You Begin Installation

    IV. Before You Begin Installation These RO units come pre-assembled on the bracket will all connections in place. These units are wet tested for leaking before they are sent to ensure there are no leaks due to assembly. Due to transit, fittings and other components may become loosened or damaged.
  • Page 4: Installation Introduction

    have higher incoming salt rather than higher hardness. For this reason, a water softener is installed behind an RO System. Due to the flow rates of a water softener, it will generally need to be installed in the following order: Feed Supply ...
  • Page 5: Filter Protection

    V. Filter Protection These systems are supplied with an inline Pressure Limiting Valve fitted to the inlet port of the system. This valve limits the pressure incoming to 50 psi (350 kPa). If your incoming pressure is below 350 kPa, you can remove the PLV as it may further reduce your incoming pressure.
  • Page 6: (C) Post Filters

    Start Up & Operation I. Commissioning NOTE: New filtration systems will require a pre-flush before being used. The GT1-20LS system will need to run for at least 15 – 20 minutes before first use to clear and residue or fines from the filters.
  • Page 7: Automation

    runs off a float switch or timer, this type of configuration allows for system downtime and helps extend the lifespan of the pump as the system is intermittently producing water When the system is installed in an open loop configuration and the pumps haven’t been allowed any downtime you may expect to see a decrease in the pumps lifespan.
  • Page 8: Parts List

    avoid getting debris on the o-ring seal. Discard the filter media and rinse the cartridge with clean water, removing and remaining DI resin. Refill the housing with resin, replace the pad and o-ring and replace the head cap. • DI Cannister Filter: Undo the housing cap and remove the DI cartridge. Unscrew the filter from the bottom and discard the DI media.
  • Page 9 3. Insufficient pump may have issues with priming and may not be able to incoming water reach its full working pressure. pressure 4. Ensure that your feed water does not exceed the specifications of the RO system. If your water contains higher 4.
  • Page 10 electrician can test the components to see if power is making it to the pumps.
  • Page 11 12 months from date of sale. If applicable, FSA may cover the return freight in the form of a re-imbursement after the system has been inspected and confirmed it is a valid warranty claim.
  • Page 12 ² Other products not manufactured or assembled by FSA are covered under the applicable manufacturer’s warranty. ³ FSA specifies recommended or required filter maintenance – see product information for further details. If a maintenance schedule is not specified, filter maintenance is required at least once per 12 month period.

Table of Contents