SECTION III. INSTALLER CHECK-OUT AND START-UP:

GENERAL:

Some of the following procedures will require the heater to be operating. Full lighting and shutdown instruc-
tions are included on the lighting and operating label affixed to the inside of the front access panel. The heater
automatically lights in response to a call for heat, and automatically shuts down when that call for heat is satisfied.
Water must be flowing through the heater during operation. Check that the pump is operating and the
system is filled with water and purged of all air prior to starting the heater.
Figure 31: Location of Components
Figure 25: Location of components
Figure 31: Location of Components
Blower
Vacuum
Switch
Blower
Vacuum
Switch
Transformer
Transformer
Gas Valve
Gas Valve
Flame Sensor
Flame Sensor
Ignitor
Access Panel
Ignitor
Gas Manifold
Access Panel
Gas Manifold

GAS LINE TESTING:

The appliance and its gas connection must be leak tested before placing the appliance in operation. The
heater and its individual shutoff valve must be disconnected from the gas supply during any pressure testing
of that system at test pressure in excess of ½ psig (3.45 kPa). The heater must be isolated from the gas sup-
ply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply
piping system at test pressure equal to or less than ½ psig (3.45 kPa).
Gas supply line must be capped when not connected. After pressure testing, reconnect the gas piping to the
gas valve. Turn gas supply "ON" and test all pipe and tubing joints for leaks. Use a soap and water solution.
Blower
Vacuum
Switch
Blower
Vacuum
Switch
Fuse Board
Fuse Board
Gas Valve
Gas Valve
Sight Glass
Sight Glass
Ignitor
Access Panel
Cover
Ignitor
Gas Manifold
Access Panel
Cover
Gas Manifold
(H250FD, H300FD, H350FD, and H400FD models)
(H250FD, H300FD, H350FD, and H400FD models)
(H150FD and H200FD models)
(H150FD and H200FD models)
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400
Keypad
Keypad
Transformer
Transformer
Ignition Control
Board
Ignition Control
Board
Blower
Blower
Air Box
Air Box
Flame Sensor
Flame Sensor
Keypad
Keypad
Ignition Control
Board
Ignition Control
Board
Fuse Board
Fuse Board
Blower
Blower
Sight Glass
Sight Glass
Air Box
Air Box
www.haywardpool.com
33