IMPORTANT:
Follow the operating instructions provided by the
manufacturer of your heating appliance. The
information below will be of assistance in a typical
gas control application, but the specific controls used
and the procedures outlined by the manufacturer or
your appliance may differ, requiring special
instructions.
Lighting the Pilot Burner Flame
STOP: READ THE WARNINGS ABOVE.
The pilot burner flame must be lit manually. If the pilot burner
flame has gone out, follow these instructions exactly.
1. Set the thermostat to its lowest setting.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn
clockwise
to OFF.
NOTE: The gas control knob can not be turned from PILOT
to OFF unless it is pushed in slightly. Do not force the
gas control knob.
5. Wait five minutes to clear out any unburned gas. If you
then smell gas, STOP! Follow ÒBÓ in the Warnings
above. If you do not smell gas, continue with the next step.
6. Remove the pilot burner access panel located below
and behind the gas control.
7. Find the pilot burner by following the metal tube from
the gas control. The pilot burner is between the two
burner tubes behind the pilot burner access panel.
8. Turn the gas control knob counterclockwise
PILOT.
Home and Building Control Home and Building Control
Honeywell
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
35 Dynamic Drive
Golden Valley, MN 55422
Scarborough, Ontario
M1V 4Z9
68-0045—3
G.R. Rev. 3-01
9. Push and hold the gas control knob all the way in.
Immediately light the pilot burner flame with a match
and continue holding the gas control knob in for one
minute after the pilot burner flame is lit.
10. Release the gas control knob and it will pop back up.
The pilot burner flame should remain lit. If pilot burner
flame goes out, repeat steps one through ten.
a. If the gas control knob does not pop up when
released, stop immediately and call your service
technician or gas supplier.
b. If the pilot flame will not stay lit after several tries,
turn the gas control knob to OFF and call your
service technician or gas supplier.
11. Turn the gas control knob counterclockwise
12. Replace the pilot burner access panel.
13. Replace the gas control access panel.
14. Reconnect all electric power to the appliance.
15. Set the thermostat to the desired setting.
Turning Off the Appliance
Vacation Shutdown
Set the thermostat to the desired room temperature while you
are away.
Complete Shutdown
Push the gas control knob in slightly and turn
clockwise
to OFF. Do not force. Appliance will
completely shut off. Follow the Lighting Procedures above to
resume normal operation.