Quick Links

APPLICATION
The VK41..R/VK81..R series gas controls with integrated
gas/air module have been developed for application in
domestic appliances with premix or atmospheric burners and
automatic ignition.
The gas/air module is designed to amplify and modulate the
outlet gas pressure by means of a pneumatic link between the
gas and air flow by using the air pressure difference.
For this system, the VK41..R series gas controls have been
designed to have the S4565 series ignition control attached
directly onto the valve.
The combined system then provides programmed safe light
up, flame supervision and regulation of gas flow to the main
burner of the appliance.
The VK41..R/VK81..R series are used in a system context in
conjunction with fan control and a direct spark ignition (DBI)
control.
The VK41..R/VK81..R series are approved in accordance with
european standards.
GAS CONTROLS WITH INTEGRATED GAS/AIR MODULE
FOR COMBINED VALVE AND IGNITION SYSTEM
VK41..R/VK81..R series
DESCRIPTION
VK41..R/VK81..R combined gas controls perform all the
functions required to safely regulate gas flow to the main
burner of domestic central heating equipment, warm air
furnaces, back boilers and water heaters.
VK41..R/VK81..R combined gas controls hold a first electric
on/off direct operator for opening the safety valve of class A or
class B according to EN161 and a second electric on/off
servo operator of class B or class C to EN 161.
VK41..R/VK81..R combined gas controls comply with the
additional requirement for class J valves according to EN 161.
The pressure regulator is in accordance with class B
requirement of EN 88.
VK41..R/VK81..R combined gas controls can handle the three
gas families, manufactured gas, natural gas and LP gas.
SPECIFICATIONS
Models
VK41.. series:
line voltage, two automatic shut off valves
for direct spark ignition (DBI) or hot surface
ignition (HSI) applications.
VK81.. series:
low voltage, two automatic shut off valves
for direct spark ignition (DBI) or hot surface
ignition (HSI) applications.
Suffix letter
R: fast opening, with integrated gas/air module
Pipe connection
Straight or elbow flanges.
Torsion and bending stress according to EN 126 group 2
Ambient temperature
0 ... 60 _C for combined valve and ignition control
0 ... 70 _C for stand alone valve
Dimensions
See fig. 1.
Pressure regulation function
Class B according to EN 88
Air pressure connections
M11 x 1
INSTRUCTION SHEET
EN1R- -9137 9808R6- -NE

Advertisement

loading

Summary of Contents for Honeywell VK41 R Series

  • Page 1 VK41..R/VK81..R series GAS CONTROLS WITH INTEGRATED GAS/AIR MODULE FOR COMBINED VALVE AND IGNITION SYSTEM INSTRUCTION SHEET DESCRIPTION VK41..R/VK81..R combined gas controls perform all the functions required to safely regulate gas flow to the main burner of domestic central heating equipment, warm air furnaces, back boilers and water heaters.
  • Page 2 Side outlet option 105** 80.8 * For 220 V DBI only ** 115 mm for threaded body A -- Side pilot outlet (optional) ”O”--ring Ø 4.47 x Ø 1.78 mm L -- Maximum pressure regulator (optional) B -- M5 x 0.8 (3) 6 mm full thread M -- M5 x 0.8 pressure feedback connection C -- ”O”--ring Ø...
  • Page 3 Amplification factor (A) (see fig. 2.) Air pressure difference The amplification factor (A) is defined with the positive air sig- air, high -- air, low nal connected to the gas/air module. Offset With a negative air signal the amplification factor is 1.0 lower Offset = P -- P air,high...
  • Page 4: Installation

    Electrical data Enclosure IP 40 Coil indication Supply voltage Accessories 220/240 V RAC 220 V, 50 Hz using rectifier Hose socket for silicone tube with 5 mm inner diameter. 240 V, 50 Hz using rectifier Order number ..... . . 45.900.402--030 24 V RAC 24 V, 50 Hz using rectifier...
  • Page 5: Maintenance And Service

    Ensure combustion chamber is free of gas before · Adjust CO % at the desired value at low output with offset start up. adjustment screw. Turn offset adjustment screw counter clockwise to increase CO Conduct a thorough check out when installation is ·...
  • Page 6 Home and Building Control Combustion Controls Center Europe Honeywell BV Phileas Foggstraat 7 7821 AJ Emmen The Netherlands Tel: +31 (- - )591 695911 Fax: +31 (- - )591 695200 http://europe.hbc.honeywell.com EN1R- -9137 9808R6- -NE...

This manual is also suitable for: