tank is sufficient.
7. Start and operate the recovery equipment
according to the manufacturer's instruc-
tions
8. Don't fill the tank to its full capacity (the liq-
uid injection volume does not exceed 80%
of the tank volume).
9. Even the duration is short, it must not
exceed the maximum working pressure of
the tank.
10. After the completion of the tank filling and
the end of the operation process, you
should make sure that the tanks and equip-
ment should be removed quickly and all
closing valves in the equipment are closed.
11. The recovered refrigerants are not allowed
to be injected into another system before
being purified and tested.
Note: Note: The identification should be made
after the appliance is scrapped and refriger-
ants are evacuated. The identification should
contain the date and endorsement. Make sure
the identification on the appliance can reflect
the flammable refrigerants contained in this
appliance.
Recovery:
1. The clearance of refrigerants in the system
is required when repairing or scrapping
the appliance. It is recommended to com-
pletely remove the refrigerant.
2. Only a special refrigerant tank can be
used when loading the refrigerant into the
storage tank. Make sure the capacity of
the tank is appropriate to the refrigerant
injection quantity in the entire system. All
tanks intended to be used for the recovery
of refrigerants should have a refrigerant
identification (i.e. refrigerant recovery tank).
Storage tanks should be equipped with
pressure relief valves and globe valves
and they should be in a good condition.
If possible, empty tanks should be evacu-
ated and maintained at room temperature
before use.
3. The recovery equipment should be kept in
a good working condition and equipped
with equipment operating instructions for
easy access. The equipment should be
suitable for the recovery of R290 refriger-
ants. Besides, there should be a quali-
fied weighting apparatus which can be
normally used. The hose should be linked
with detachable connection joint of zero
leakage rate and be kept in a good condi-
tion. Before using the recovery equipment,
check if it is in a good condition and if it
gets perfect maintenance. Check if II elec-
Air conditioner portable
trical components are sealed to prevent
the leakage of the refrigerant and the fire
caused by it. If you have any question,
please consult the manufacturer.
4. The recovered refrigerant shall be loaded
in the appropriate storage tanks, attached
with a transporting instruction, and
returned to the refrigerant manufacturer.
Don't mix refrigerant in recovery equip-
ment, especially a storage tank.
5. The space loading R290 refrigeration can't
be enclosed in the process of transporta-
tion. Take anti electrostatic measures if
necessary in transportation. In the process
of transport, loading and unloading, nec-
essary protective measures must be taken
to protect the air conditioner to ensure that
the air conditioner is not damaged.
6. When removing the compressor or clearing
the compressor oil, make sure the com-
pressor is pumped to an appropriate level
to ensure that there is no residual R290
refrigerants in the lubricating oil. The vacu-
um pumping should be carried out before
the compressor is returned to the supplier.
Ensure the safety when discharging oil from
the system.
15