Download Print this page
Mitsubishi Electric FR-A8TAT Quick Start Manual

Mitsubishi Electric FR-A8TAT Quick Start Manual

Control circuit terminal block intercompatibility attachment

Advertisement

Quick Links

INVERTER
Control Circuit Terminal Block
Intercompatibility Attachment
<FR-A8TAT>
Thank you for choosing this Mitsubishi Electric inverter option unit.
This Instruction Manual provides handling information and precautions for use of the equipment. Incorrect handling
might cause an unexpected fault. Before using this product, always read this Instruction Manual carefully to use this
product correctly.
Please forward this Instruction Manual to the end user.
Warning
 While the inverter power is ON, do not open the front cover or the wiring cover. Do not run the inverter with the
front cover or the wiring cover removed. Otherwise you may access the exposed high voltage terminals or the
charging part of the circuitry and get an electric shock.
 Even if power is OFF, do not remove the front cover except for wiring or periodic inspection. You may accidentally
touch the charged inverter circuits and get an electric shock.
 Before wiring or inspection, LED indication of the operation panel must be switched OFF. Any person who is
involved in wiring or inspection shall wait for at least 10 minutes after the power supply has been switched OFF
and check that there are no residual voltage using a tester or the like. The capacitor is charged with high voltage
for some time after power OFF, and it is dangerous.
 Any person who is involved in wiring or inspection of this equipment shall be fully competent to do the work.
 Do not touch the printed circuit board or handle the cables with wet hands. Otherwise you may get an electric
shock.
 Do not subject the cables to scratches, excessive stress, heavy loads or pinching. Otherwise you may get an
electric shock.
1
Unpacking and checking the product
Take the product out of the package, and confirm that the product is as you ordered and intact.
The product is an option for the FR-A800 series.
FR-A8TAT
Installation screw (M36)
1
2

Used with the FR-A820-01250 (22K) or lower and FR-A840-00620 (22K) or lower.

Used with the FR-A820-01540(30K) or higher and FR-A840-00770(30K) or higher.
• Applicable control circuit terminal blocks
• FR-A700 series
• FR-A500 series
Hexagon spacer
Bracket


1
1
1/4
2
Installation procedure
(1) Loosen the two installation screws at the both sides of the control circuit terminal block of FR-A800
series inverter. (These screws cannot be removed.)
Slide down the control circuit terminal block to remove it.
Loosen the screws.
For the FR-A820-01250(22K) or lower or the FR-A840-00620(22K) or lower inverter, remove the
fixing screw for earthing (grounding) cable, and instead attach the provided hexagon spacer.
(Tightening torque: 0.33 to 0.4 Nm)
For the FR-A820-01540(30K) or higher or the FR-A840-00770(30K) or higher inverter, fit the
bracket to the inverter, into the place shown in the figure below.
FR-A820-01250 (22K) or lower
FR-A840-00620 (22K) or lower
Hexagon spacer
Remove the screw.
(2) Install the A8TAT. Be careful not to bend the pins of inverter control circuit connector.
(3) For the FR-A820-01250(22K) or lower or the FR-A840-00620(22K) or lower inverter, fix the A8TAT
to the inverter and the hexagon spacer using the provided installation screws. (Tightening torque:
0.33 to 0.4 Nm)
For the FR-A820-01540(30K) or higher or the FR-A840-00770(30K) or higher inverter, fix the
A8TAT to the inverter and the bracket using the provided screws. (Tightening torque: 0.33 to 0.4
Nm)
Example of FR-A820-00105 (1.5K)
FR-A820-01540(30K) or higher
FR-A840-00770(30K) or higher
Insert the bracket into the tab.
Bracket
Fix with screws.
2/4
IB(NA)-0600541ENG-A

Advertisement

loading

Summary of Contents for Mitsubishi Electric FR-A8TAT

  • Page 1 For the FR-A820-01250(22K) or lower or the FR-A840-00620(22K) or lower inverter, remove the fixing screw for earthing (grounding) cable, and instead attach the provided hexagon spacer. Thank you for choosing this Mitsubishi Electric inverter option unit. (Tightening torque: 0.33 to 0.4 Nm) This Instruction Manual provides handling information and precautions for use of the equipment.
  • Page 2 (4) Install the control circuit terminal block of the FR-A700/A500 series inverter. Be careful not to bend REVISIONS the pins of A8TAT control circuit connector. Fix the control circuit terminal block using the installation screws of the control circuit terminal block. (Tightening torque: 0.33 to 0.4 Nm) Print date * Manual number Revision...