We recommend installing the appliance in a well-ventilated
environment, or under an extraction hood to remove the fumes or
vapours produced during the cooking cycle.
The appliance has an equipotential earth terminal "N" (fig.2) at the
back.
The appliance can be installed alone or in line.
Respect a minimum distance of 80mm between the appliance and
any walls made of flammable material, partitions, kitchen furniture or
nearby equipment.
When checking for leaks do not use naked flames!
The manufacturer shall not be held responsible and the guarantee is void in the case of damage caused by negligence in
following the operating and installation instructions or by improper use. The guarantee is void in the case of connections which
have been made in a way which doesn't meet the current standards and fire-fighting regulations.
This unit belongs to construction type (A1), therefore it does not have to be connected to a flue.
The distribution network pressure must meet the following
specifications:
ALLOWED
LPG
NOT ALLOWED
ALLOWED
METHANE
H
NOT ALLOWED
If the gas distribution network pressure on the installation site doesn't
meet the above values, inform the gas board and do not turn the unit
on until the cause and a solution have been found.
Evacuation of unburnt gases

Checking the pressure

From 20/25 to 35/45 mbar
Below 20/25 above 35/40 mbar
From 17 to 25 mbar
Below 17 above 25 mbar
The contact surfaces must be covered with non-combustible heat
insulating material.
After installing the appliance check for any leaks in the fittings. Use
non-corrosive foam products, such as leak detection sprays, to look
for any leaks.
The distribution network pressure can be taken with a "Um"
manometer (min. definition 0.1 mbar), connected to the pressure
outlet behind control panel "H" (fig.6).
1.
Remove the control panel.
2.
Remove the screw and sealing washer (fig.6) from the pressure
outlet and connect the manometer.
3.
Turn the appliance on following the enclosed instructions and
check that the pressure is within the permitted pressure range.
4.
Disconnect the manometer and replace the screw and the
sealing washer in the pressure outlet.
5.
Reassemble the appliance.