Pipe Diameter (Liquid / Gas)
Standard length
Length range (min – max)
I/D & O/D Height different
Additional Gas Amount
Length for Additional Gas
Drain Hose
Indoor Heat
Exchanger
Outdoor Heat
Exchanger
Air Filter
Power Supply
Power Supply Cord
Thermostat
Protection Device
Indoor Operation Range
Outdoor Operation Range
1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air
temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb).
2. Specifications are subjected to change without prior notice for further improvement.
Inner Diameter
Length
Fin Material
Fin Type
Row x Stage x FPI
Size (W x H x L)
Fin Material
Fin Type
Row x Stage x FPI
Size (W x H x L)
Material
Type
mm (inch)
m (ft)
m (ft)
m (ft)
g/m (oz/ft)
m (ft)
mm
mm
mm
mm
A
Dry Bulb
Maximum
Minimum
Maximum
Minimum
6
6.35 (1/4) / 12.70 (1/2)
7.5 (24.6)
3 ~ 15 (9.8 ~ 49.2)
5 (16.4)
10 (0.1)
7.5 (24.6)
16
550
Pre Coat
Slit Fin
2 x 15 x 21
610 x 315 x 25.4
Blue Coated
Corrugated Fin
1 x 20 x 17
22 x 508 x 708.4
Polypropelene
One-touch
Indoor
15
-
-
Wet Bulb
32
16
52
16
23
11
31
11