8
Remove the tapes and connect the power supply cord and connecting cable between indoor unit and outdoor
unit according to the diagram below.
9
Secure the power supply cord and connection cable onto the control board with the holder.
10 Fix back metal cover to original position without damaging alluminium foil. Ensure metal cover is fitted at both
end.
Note:
•
Isolating Devices (Disconnecting means) should have minimum 3.0mm contact gap.
•
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's respectively.
•
Earth wire shall be Yellow/Green (Y/G) in colour and longer than the other AC wires as shown in the figure for the
electrical safety in case of the slipping out of the cord from the anchorage.
10.2.5 Wire Stripping and Connecting Requirement
30