Lever 5-hole bath set with pull-out hand shower & deck diverter rough, to suit k1-2201, x1-1056, m1-2201, m1-2202, m1-2205,m1-2206, m1-2208, m1-2209, m2-2201, m2-2202 (10 pages)
Dimensions in Inches (& Millimetres) 8"~12" (203mm~305mm) 4-1 13/16-20UN-2A 4-Ø1 7/16" (4-Ø36mm) 1 1/4-18UNEF-2A 1 1/4-18UNEF-2A 1 1/16-18UNEF-2A 1/2-14NPSM-2A M15X1-6g Whilst every effort is made to ensure accuracy, design and dimensions are subject to change without notice as part of the company’s product development process.
Installation Procedure Steps 1-3 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Remove the protective bubble bag, cap, top mounting nut from body assembly, and remove plug from spout tube assembly and shower hose top.
Page 5
Installation Procedure Steps 4-5 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. Shut off main water supply before installation. Replace the protective bubble bag, body and spout protective caps/plugs and shower hose top to prevent dirt ingress or water leakage during construction.
Parts List Exploded view Cartridge ( C ) (507724-50) Protective cap (038103) O-ring (004074N) Side body (014638) Cartridge ( H ) (507145-50) O-ring (048034N) Nut (009331) Pulling rod (125455) Adaptor (200198) Sleeve (041837) Spring (005626) Clip (012294) Oil-seal (010022) Diverter rod (208340) Hose (105786) Nut (054026) O-ring (004673)
Fault Finder Fault Cause Rectification Leaks around handle. Cartridge has come loose or Tighten/reinstall the cartridge or damaged. replacement the cartridge if it is damaged.
Safety Tips, Care and Maintenance Safety Tips If you are soldering during faucet installation,remove cartridges, seats, gaskets and washers prior to applying flame, otherwise you will void the warranty. Cover drain openings to avoid losing small parts. When cutting or soldering pipe, use safety glasses to protect your eyes. Important Points Prior to beginning installation.
Not Covered by this Guarantee Damage or defects arising from incorrect installation, improper use or lack of maintenance. Installed product damaged in transit Consequential loss, damage or product removal and installation costs. Lefroy Brooks is not responsible for any on site labour charges.
Page 10
TELEPHONE: 718-302-5292. FAX: 718-302-4177 The use of trademarks, product design and artwork is subject to licence or agreement with Christo A. Lefroy Brooks. The design registrations, trademark registrations and copyrights are protected by law and the use or reproduction outside the terms of an agreement is prohibited.
Need help?
Do you have a question about the R1-4025 and is the answer not in the manual?