BREATHING AIR FILTER set B-AIR™
Please read the following instructions carefully before installing the filter into the service.
Trouble-free and safe operating of the filter can only be guaranteed if recommendations
and conditions stated in this manual are respected.

Advertisement

Table of Contents
loading

Summary of Contents for OMEGA AIR B-AIR 0076

  • Page 1 Installation and operating manual BREATHING AIR FILTER set B-AIR™ Please read the following instructions carefully before installing the filter into the service. Trouble-free and safe operating of the filter can only be guaranteed if recommendations and conditions stated in this manual are respected.
  • Page 2 Components Part 1 Wall assembly kit 2 Pressure drop indicator 3 Automatic drain 4 Manual drain 5 B-AIR housing 6 Housing O-ring 7 Filter element...
  • Page 3: Technical Data

    Technical data FLOW CAPACITY DIMENSIONS [mm] WEIGHT FILTER PIPE SIZE FILTER VOLUME [kg] [inch] ELEMENT [scfm] B-AIR 0076 / ” 07050 (XS+H 3x0,45 B-AIR 0106 / ” 14050 (XS+H 3x0,64 B-AIR 0186 ” 12075 (XS+H 3x1,4 B-AIR 0306 ” 22075 (XS+H...
  • Page 4: Safety Instructions

    PRESSURE EQUIPMENT DIRECTIVE PED 2014/68/EU (Fluid group 2) B-AIR 0076 – B-AIR 0476 Not required B-AIR 0706 Category 1, Module A There is Technical datasheet available. For additional technical specification, contact manufacturer. Safety instructions The relevant safety at work and accident prevention regulations, plus operating instructions, shall apply for operating the filter.
  • Page 5: Appropriate Use

    • Depressurize the system before carrying out the installation work. The unit must be installed vertically in the piping. • Ensure that the filter is installed without any stress. • Use original spare parts only. • Use the device for an appropriate purpose only. •...
  • Page 6: Installation

    Installation Operations should be performed only by qualified personnel. Never operate with installation under pressure. The user is responsible for ensuring that the filter never operates at a pressure exceeding the nominal values. • It is recommended to include a shut-off valve with removable coupling at the air inlet for easier maintenance.
  • Page 7: Maintenance

    Maintenance Hazard due to a sudden release of pressure! Never remove any parts of the filter for as long as the filter is still pressurized! Depressurize the filter before carrying out any work on the filter. Filter elements are subject to wear. To maintain system efficiency, optimal performance, and best air quality, these rules of proper maintenance should be followed: If installed, check the pressure drop indicator regularly to ensure the filter element is not •...