Technical Data - AEG HG694340 User Manual

Table of Contents

Advertisement

CAUTION!
Install the appliance only on
a worktop with flat surface.
8.9 Possibilities for insertion
The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance
intervention is necessary.
Kitchen unit with door or drawer

9. TECHNICAL DATA

9.1 Hob dimensions
Width
Depth
9.2 Bypass diameters
BURNER
Rapid
Semi-rapid
Auxiliary
9.3 Other technical data
TOTAL POWER:
Electric supply:
min 6 mm
Ø BYPASS 1/100 mm
42
32
28
Gas original:
Gas replacement:
220-240 V ~ 50/60 Hz
3 core flexible cable with non rewireable plug fitted with a 3 amp
cartridge fuse
b
min 5 mm
(max 150 mm)
60 mm
A. Removable panel
B. Space for connections
Kitchen unit with oven
The electrical connection of the hob and
the oven must be installed separately for
safety reasons and to let easy remove
oven from the unit.
590 mm
520 mm
G20 (2H) 20 mbar = 7,7 kW
G30 (3+) 28-30 mbar = 545 g/h
G31 (3+) 37 mbar = 536 g/h
ENGLISH
17
a
min 30 mm

Advertisement

Table of Contents
loading

Table of Contents