GEDA 1500z Original Operating Manual page 78

Construction hoist/transport platform
Table of Contents

Advertisement

Malfunctions - Diagnosis – Repair
Releasing the safety gear (only by a qualified person)
 Remove the dummy plug (1).
 Insert the drop test control on the plug
connection (2) on the trolley switch cabinet.
 Press the UP button (3) from outside the
platform and move the platform up by
approx. 20-30 cm.
After "neutral" running, disconnect the drop
test control again and plug in the dummy
plug (1) on the plug-in connection (2).
 Release the lock nut (4) on the
safety gear.
 Turn the safety-gear protective
cover (5) to the left until the limit
switch lug (6) engages in the slot
of the protective cover (5).
 Re-tighten the lock nut (4).
After the safety gear has activated, it must be checked for signs of
damage. The check, carried out by a competent person, is
described in the maintenance manual.
Operating Manual
6
78 / 84
®
GEDA
1500 Z/ZP
2
3
5
BL076 GB Edition 07.2015
1
4

Advertisement

Table of Contents
loading

Related Products for GEDA 1500z

This manual is also suitable for:

1500zp

Table of Contents