DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using a rigid pipe ø 160 or 125mm, the choice of which
is left to the installer.
To install a ø 160 pipe
• To install the dumper 10
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
To install a ø 125 pipe
• To install a ø 125 mm air exhaust connection, insert the
reducer flange 9 on the dumper 10.
• Fix the pipe in position using sufficient pipe clamps (not
supplied).
• Remove any activated charcoal filters.
AIR OUTLET – RECIRCULATION VERSION
• Connect the Flange to the air outlet opening using a rigid or
flexible pipe of ø125 or 160 mm.
• To connect using a ø125 mm pipe, insert the reduction Flange
9 onto the Hood canopy outlet.
• Fasten the pipe using suitable pipe clamps. The materials
required to do so are not provided.
• Fix the directional Grid 8 on the outlet, using 2 screws 12e (2.9
x 9.5) provided.
• Make sure that the activated charcoal filters are present (see
paragraph on Activated Charcoal Filter Maintenance).
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch
having a contact gap of at least 3 mm..