Corrective Maintenance

The TD 100 handpiece features a replaceable O-ring that protects
the contact area from flux fume and other contamination. The O-
ring may need to be replaced over time. To replace the O-ring
follow the procedure below:
1. Disconnect the TD 100 from the power source
2. Remove the tip cartridge
3. Unscrew the cap from the back of the TD 100
4. Slide the connector assembly out of the handle
©2012 PACE Inc., Southern Pines, North Carolina