Safety Guidelines

The following are safety precautions that personnel must understand and follow when using or servicing
this product.
1. POTENTIAL SHOCK HAZARD - Repair procedures on PACE products should be performed
by Qualified Service Personnel only.
equipment is disassembled. Service personnel must avoid contact with these parts when
troubleshooting the product.
2. To prevent personnel injury, adhere to safety guidelines in accordance with OSHA and other
applicable safety standards.
3. Heater Cartridge Tips are hot when the handpiece is powered on and for a period of time
after power off. DO NOT touch the cartridge. Severe burns may result.
4. PACE Tip & Tool Stands and handpiece cubbies are designed specifically for use with the
associated handpiece and houses it in a manner that protects the user from accidental burns.
Always store the handpiece in its holder. Be sure to place the handpiece in its holder after
use and allow for cooling before storing.
5. Always use PACE systems in a well ventilated area. A fume extraction system such as those
available from PACE are highly recommended to help protect personnel from solder flux
fumes.
6. Exercise proper precautions when using chemicals (e.g., solder paste). Refer to the Material
Safety Data Sheet (MSDS) supplied with each chemical and adhere to all safety precautions
recommended by the manufacturer.

Handpiece Connection

Connect the handpiece connector plug into the Power Receptacle in the following
manner.
1. Align guide on the connector with slot on power receptacle.
2. Insert connector into power receptacle.
3. Turn the connector housing clockwise to lock in place.

Tip Cartridge Installation

Both TD-100 and MT-100 tip cartridges are fitted with a key lock device. This feature ensures that tip
cartridges are held firmly in position and will maintain their orientation. MT-100 tip cartridges CANNOT be
fully inserted into the TD-100 and TD-100 tip cartridges CANNOT be fully inserted into the MT-100. To
install a tip cartridge, please follow the procedure below.
1. Line up the key lock feature on the tip cartridge with the notch on the front
of the handpiece.
2. Push the tip cartridge all the way into the handpiece.
To remove a tip cartridge, use the included hot grip removal pad to grasp the tip cartridge and pull
the tip cartridge out of the handpiece. Be careful when completing this procedure as the tip cartridge
may be hot and direct contact can cause injury.
cartridges can be changed at any time and without turning off the power to the unit.
©2012 PACE Inc., Southern Pines, North Carolina
All Rights Reserved
Line voltage parts may be exposed when the
Tips
Page 3 of 11