Dsim Module Status Led Essentials - aci DSIM-SS Installation Manual

Table of Contents

Advertisement

®

6. DSIM Module Status LED Essentials

Operation Blinking Patterns for DSIM Module:
LED Blinking Pattern
Steady Repeating Blue Dashes
Series of Blue Blinks
Single Blue Long Dash Between Series
of Blue Blinks
2 Blue Long Dashes Between Series
of Blue Blinks
3 Blue Long Dashes Between Series
of Blue Blinks
Quick Blue / Orange Blinks
LED Fault Conditions Blinking Patterns
LED Blinking Pattern
Steady on Pink
Steady Repeating Orange Blinks
Quick Blue / Orange Blinks
Note 2: The DSIM LED blinks after the pilot channel count will be orange during
programming and blue when in operation
Indications
Manual Mode
Pilot Channel Number ‐ See tables in section 9
at the end of the guide for blinking sequences
Analog channel is set
Digital channel is set
TGC Mode‐ The default cable length setting for
TGC mode is 27 dB of cable in front of the
amplifier
Pilot paste in progress‐Wait
or Pilot channel not found or lost
Indications
24 volt input into DSIM module is out of the
operational range of 21.5 to 26.5 VDC. If this
occurs, check for correct AC voltage input to the
amplifier and for correct output DC voltage of
internal power supply to the RF module
Temperature in DSIM module is too high / low
(above 221ºF/105ºC or below -40ºF/-40ºC)
Pilot Lost; DSIM automatically switches to
Thermal (TGC) mode until Pilot channel is
restored.
.
Page 9 of 18
DSIM-SS
Installation Guide Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsim-a

Table of Contents