4. DSIM Controller Operation Instruction Guidelines

Switch
+
-
Mode
Mode Change
Note 1: Making adjustment to the output levels is only recommended when setting up the
DSIM modules in temperatures bellow 32ºF / 0ºC or above 104ºF / 40ºC.

5. DSIM Controller Status LED Essentials

LED Blinking Pattern
Quick Blue / Red Blinks
Steady on Blue
Series of Blue Blinks
Steady on Purple
Function
In MGC Mode, Click to increase RF output level
(See Note 1)
Increase
In AGC Mode, no function
In TGC Mode, Click to increase cable length value
In MGC Mode, Click to decrease RF output level
(See Note 1)
Decrease
In AGC Mode, no function
In TGC Mode, Click to decrease cable length value
In MGC mode, Click to go to Align Mode to load
controller channel setting, DSIM module will then
automatically switch to AGC mode
In AGC Mode, Click to return to TGC Mode
In TGC Mode, Click to go to MGC Mode
Description
Indications
DSIM controller to module syncing process -
Occurs when controller is installed into the DSIM
module.
Aligning process: in progress
In MGC Mode
In AGC Mode
In TGC Mode