DSIM Mode Flow Chart
This is the default mode for Amp. Setup
The controller LED will be solid blue
The DSIM LED will blink blue every half sec
Press MODE
once to start the
align process
Align Process:
This takes 45 sec. to lock on to the pilot CH.,
and save the pilot level
The controller will flash blue/ red
The DSIM will flash CH & type pattern
If the pilot is too
low, the DSIM
will use the
TGC process
Align Process: Thermal Fallback
If the Align Process fails check/ adjust levels or
reduce AGC PAD. return the MGC mode to try
again. DO NOT leave the DSIM in this mode.
The controller will flash blue/ red
The DSIM will flash blue/ orange
Press MODE once to return to MGC mode
MGC mode:
DSIM Locks on to the
channel successfully, it
starts the AGC mode
Press MODE
once from any
of these 4
modes to go to
TGC mode
TGC mode:
This mode calculates the output level based on
the internal Amp. Temperature
The controller LED will be solid purple
The DSIM LED will give the cable length
(9, 18, 27) dB and three long blinks
Page 7 of 18
Installation Guide Rev B
AGC mode:
The DSIM will maintain pilot level stability
The controller will blink blue every half sec.
The DSIM LED will give a channel &
ch type pattern
If the pilot drop
more than 10
dB the DSIM
will go to
thermal fallback
AGC mode: Thermal Fallback
The DSIM will calculate the output level until the
pilot channel returns. Then the DSIM will resume
AGC mode.
The controller will blink blue every half sec
The DSIM will flash blue/ orange