Lincoln Electric LN-25X Operator's Manual page 22

Hide thumbs Also See for LN-25X:
Table of Contents

Advertisement

LN-25X™
Setup Menu Item
Display
Wire feed speed units
PrE / FLo
Preflow time
Run in wire feed speed
burn /
Burnback time
POSt /
Postflow time
Display of actual wire
dISP
feed speed or arc
current
Arc hours display on/off
After weld display hold
hoLd
time
True Voltage
Technology (TVT)
enable/disable
CrossLinc™
CroS /
LInC
enable/disable
CC or CV power source
*K3519-2 has a factory default of EURO
Left
Right
Display
US / Euro
OFF / 0.10 -
10.0
OFF/ 10 /
run
20/ 30 / 40/
50
OFF / 0.030
bAC
- 0.250
OFF / 0.10 -
Flo
10.0
Curr / FEEd
hrS
OFF / On
5 or 300 /
SEC
tUt
OFF / On
OFF / On
CV / CC
Factory
Default
Changes the display of wire feed speed between inches per
US*
minute (US) and meters per minute (Euro)
The preflow timer range is OFF to 10 seconds. Preflow time
is the time delay from when the trigger is pulled to when the
OFF
wire starts to feed and is energized. Preflow is used to purge
the welding gun with shielding gas and helps to minimize
porosity at the start of the weld.
"Run-in" refers to the wire feed speed during the time from
when the trigger is pulled to when an arc is struck. The Run-
In range is Off, 10%,20%,30%,40%,50% of the set welding
wire feed speed.When a number is displayed, the Run-in
wire feed speed is that percentage of the welding wire feed
OFF
speed until an arc is struck. When Run-in is "OFF", the wire
feed speed is the same as the welding wire feed speed. Turn
Run-In "OFF" for fast, crisp starts, especially when running
with .035 or .045 (0.9 or 1.2mm) solid steel wires at high
wire feed speeds.
The burnback timer controls the additional amount of time
the power source output remains ON after the wire drive has
stopped feeding wire. The range for Burnback is Off, 0.10-
OFF
10sec. Burnback adjustment prevents the wire from sticking
to the weld at the end of a weld and helps to condition the
wire for the next weld.
Postflow is the time from when the power source output
turns off until the postflow timer expires. The range for
OFF
Postflow gas time is Off, .1-10sec. Use postflow to protect
the weld while the weld cools.
The left display can show either amperage (CUrr) or actual
Curr
WFS (FEEd) during welding.
When on, the cumulative arc hours and arc minutes will be
OFF
displayed at power on.
The display of the actual wire feed speed or amperage and
5
voltage after welding has stopped will be held for either 5
seconds or 300 seconds.
On
Turns TVT functionality on or off.
Turns CrossLinc™ functionality on or off. TVT is operational
On
only when CrossLinc™ is on.
By default, CrossLinc is active and it is assumed the Activ8X
is being used with a CV output power source. In this case,
voltage will be presettable at the feeder and WFS will be the
CV
actual WFS. When used with a CC output only power
source, voltage will not be presettable at the feeder and WFS
will be a function of the WFS setting and the actual welding
voltage. (refer to Fig B.4)
B-6
OPERATION
Description

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents