Daikin BRC7C510W Operation Manual

Daikin BRC7C510W Operation Manual

Wireless remote controller kit

Advertisement

Quick Links

Wireless Remote Controller Kit
MODELS:
BRC7C54W
BRC7C59W
BRC7C510W
BRC7C511W
Thank you for purchasing this Daikin air conditioner.
Carefully read this operation manual before using the air conditioner.
It will tell you how to use the unit properly and help you if any trouble occurs.
After reading the manual, file it away for future reference.
Vielen Dank für den Kauf einer Klimaanlage von Daikin.
Bitte lesen Sie diese Bedienungsanleitung vor der Inbetriebnahme des Gerätes
gründlich durch. Hier wird erklärt, wie das Gerät richtig eingesetzt wird und was bei
Störungen zu tun ist.
In dieser Anleitung wird nur das Innenaggregat beschrieben.
Verwenden Sie diese Anleitung zusammen mit der Bedienungsanleitung des
Außenaggregats.
Nach dem Lesen der Anleitung legen Sie diese griffbereit zum Nachschlagen auf.
Nous vous remercions pour votre acquisition de ce climatiseur Daikin.
Lisez attentivement ce manuel avant d'utiliser le climatiseur.
Il vous expliquera comment vous servir correctement de l'appareil et vous guidera
en cas de problème.
Lorsque vous aurez lu le manuel, rangez-le afin de pouvoir vous y référer
ultérieurement.
Le agradecemos la compra de este acondicionador de aire Daikin.
Lea cuidadosamente el manual de funcionamiento antes de utilizar el
acondicionador de aire.
Dicho manual le indicará cómo utilizar adecuadamente la máquina y le ayudará
en caso de avería.
Después de leer el manual, consérvelo para consultas futuras.
OPERATION MANUAL
BRC7CA510W
BRC7CA511W
English
Deutsch
Français
Español
Italiano
ëëçíéêÜ
Nederlands
Portugues

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BRC7C510W and is the answer not in the manual?

Questions and answers

Summary of Contents for Daikin BRC7C510W

  • Page 1 Außenaggregats. ëëçíéêÜ Nach dem Lesen der Anleitung legen Sie diese griffbereit zum Nachschlagen auf. Nous vous remercions pour votre acquisition de ce climatiseur Daikin. Lisez attentivement ce manuel avant d’utiliser le climatiseur. Nederlands Il vous expliquera comment vous servir correctement de l’appareil et vous guidera en cas de problème.
  • Page 2 Θα σαò πουν πωò θα χρησιìοποιÞσετε σωστÜ τη ìονÜδα και θα σαò βοηθÞσουν αν εìφανιστοýν προβλÞìατα. Αφοý διαβÜσετε τιò οδηγßεò, ΒÜλτε τιò στσ αρχεßο σαò για ìελλοντικÞ αναφορÜ. Wij danken u voor de aankoop van deze Daikin airconditioner. Lees deze bedrijfshandleiding aandachtig door voordat u de airconditioner gebruikt.
  • Page 3: Prior To Use

    PRIOR TO USE This operation manual is exclusively for instructions on how to use the wireless remote controller. Read also the operation manual attached to the indoor unit for safe usage of the system and maintenance. VOR DER INBETRIEBNAHME Diese Betriebsanleitung enthält ausschließlich Anweisungen über den Gebrauch der drahtlosen Fernbedienung.
  • Page 4 ON OFF DOWN ON OFF TEMP TIME DOWN RESERVE CANCEL TIMER TEST MODE SWING TEST TEST COOL/HEAT CHANGEOVER REMOTE CONTROL SWITCH...
  • Page 5 ON OFF ON OFF TEMP DOWN TIME DOWN RESERVE CANCEL TIMER MODE SWING /TEST ON OFF ON OFF TEMP DOWN TIME DOWN RESERVE CANCEL TIMER MODE SWING /TEST...
  • Page 6 ON OFF ON OFF ON OFF TEMP TEMP TEMP TIME TIME TIME DOWN DOWN DOWN RESERVE CANCEL RESERVE CANCEL RESERVE CANCEL TIMER TIMER TIMER MODE MODE MODE SWING SWING SWING /TEST /TEST /TEST ON OFF ON OFF ON OFF ON OFF ON OFF ON OFF TEMP...
  • Page 7 ΠροϋποθÝσειò απüρριψηò Disposal requirements Οι ìπαταρßεò που παρÝχονται ìε το τηλεχειριστÞριο φÝρουν αυτü το σýìβολο. Batteries supplied with the remote controller are marked with this symbol. Αυτü σηìαßνει üτι οι ìπαταρßεò πρÝπει να απορρßπτονται χωριστÜ απü τα This means that the batteries shall not be mixed with unsorted household waste. οικιακÜ...
  • Page 8: Table Of Contents

    CONTENTS After reading, keep this manual in a con- venient place so that you can refer to it PRIOR TO USE ......[1] whenever necessary. If the equipment is ILLUSTRATION....... [2] transferred to a new user, be sure also to hand over the manual.
  • Page 9 Consult your local dealer regarding Do not start or stop operating the air what to do in case of refrigerant leak- conditioner with the power supply age. breaker turned ON or OFF. When the air conditioner is to be installed Otherwise, fire or water leakage may in a small room, it is necessary to take result.
  • Page 10 Do not place objects that are suscepti- Do not place water containers (flower ble to moisture directly beneath the vases, etc.) on the unit, as this may indoor or outdoor units. result in electric shocks or fire. Under certain conditions, condensation Do not install the air conditioner at any on the main unit or refrigerant pipes, air place where there is a danger of flam-...
  • Page 11: Names And Functions Of The

    Do not place objects in direct proxim- 2. NAMES AND FUNCTIONS ity of the outdoor unit and do not let OF THE OPERATING SEC- leaves and other debris accumulate around the unit. TION (Fig. 1, 2) Leaves are a hotbed for small animals which can enter the unit.
  • Page 12 PROGRAMMING TIMER BUTTON FAN/AIR CONDITIONING SELECTOR SWITCH Use this button for programming “START and/or STOP” time. (Operates Set the switch to “ ” (FAN) for FAN with the front cover of the remote con- and “ ” (A/C) for HEAT or COOL. troller opened.) COOL/HEAT CHANGEOVER SWITCH TIMER MODE START/STOP BUTTON...
  • Page 13: Handling For Wireless Remote Controller

    Placing the remote controller in the 3. HANDLING FOR WIRELESS remote controller holder REMOTE CONTROLLER Install the remote controller holder to a wall or a pillar with the attached screw. (Make Precautions in handling remote con- sure it transmits) troller Direct the transmitting part of the remote controller to the receiving part of the air Placing the...
  • Page 14: Operation Range

    Con- controller’s setting. tact your Daikin dealer to confirm your sys- In this case, contact your DAIKIN dealer. tem types. • To protect the unit, turn on the main power switch 6 hours before operation.
  • Page 15 Press ON/OFF button. [°C] • • OPERATION lamp lights up and the system Setting starts OPERATION. temperature 〈〈FOR SYSTEMS WITH COOL/HEAT Note: CHANGEOVER REMOTE CONTROL SWITCH (Fig. 4)〉〉 • The setting is impossible for fan operation. Select OPERATION MODE with Press FAN SPEED CONTROL the COOL/HEAT button.
  • Page 16 STOPPING THE SYSTEM • Hot air is circulated to warm the room. It will take some time from when the air con- Press ON/OFF button again. ditioner is first started until the entire room becomes warm. The internal fan automat- OPERATION lamp goes off and the system ically turns at low speed until the air condi- stops OPERATION.
  • Page 17 ADJUSTING THE AIR FLOW PROGRAM TIMER OPERATION (Fig. 8) DIRECTION (Fig. 7) • The timer is operated in the following two Press the AIR FLOW DIRECTION ADJUST ways. button to adjust the air flow angle. Programming the stop time ( ..The system stops operating after the Press the AIR FLOW DIREC- time setting has elapsed.
  • Page 18 〈〈For Heat recovery system〉〉 For example. When the timer is When one BS unit is connected with several programmed to stop indoor units. ON OFF the system after TEMP 3 hours and start the TIME system after Outdoor unit 4 hours, the system DOWN will stop after RESERVE CANCEL...
  • Page 19 The machine runs in the previous mode. NOTE The system operates with the previously set Contact your Daikin dealer in case of air flow direction. changing the combination or setting of group control and two remote controller control systems.
  • Page 20: Malfunction Of The Air Conditioner

    Press the INSPECTION/TEST 6. MALFUNCTION OF THE button to select the inspection AIR CONDITIONER mode “ ”. The following symptoms do not indi- “ ” appears on display and blinks. “UNIT” cate air conditioner malfunction lights up. Press PROGRAMMING TIMER I.
  • Page 21 II. IN CASE BESIDES EMERGENCY STOP Contact the place of purchase in the fol- lowing case. 1. The unit does not operate at all. • Check if the receiver is exposed of sun- light or strong light. Keep receiver away WARNING from light.
  • Page 22 3P107422-5S EM97A030E (0807) HT FS...

This manual is also suitable for:

Brc7c511Brc7c54wBrc7c59wBrc7ca510wBrc7ca511w

Table of Contents