This document explains how to connect to the REM-11178. Note The guidelines in this document are specific to the REM-11178. The other components in the system might not meet the same safety ratings. Refer to the documentation for each component in the system to determine the safety and EMC ratings for the entire system.
Furthermore, any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules. Preparing the Environment Ensure that the environment in which you are using the REM-11178 meets the following specifications. Operating temperature -25 °C to 60 °C...
Verifying the Kit Contents Verify that the following items are included in the REM-11178 kit. Figure 1. REM-11178 Kit Contents 1. NI REM-11178 3. Supply voltage connector 2. Bus connector 4. Spring-terminal block (x4) Unpacking the Kit Caution To prevent electrostatic discharge (ESD) from damaging the device, ground yourself using a grounding strap or by holding a grounded object, such as your computer chassis.
Page 4
White Bus coupler, power module Installing Bus Connectors What to Use • Bus connector • DIN rail What to Do Complete the following steps to install bus connectors on the DIN rail. 4 | ni.com | REM-11178 Getting Started Guide...
Page 6
Note Verify that the bus connector socket aligns with the socket on the underside of the module. Press the REM-11178 directly onto the bus connector and DIN rail until it clicks into place. Caution Tilting the module when mounting it on the DIN rail will damage the contacts.
Page 8
Green Flashing Data is invalid or unavailable. The REM-11178 cannot communicate with the Green/Yellow Flashing connected devices. The REM-11178 did not detect a valid cycle after Solid power-on. Yellow Flashing The REM-11178 is not part of the configuration. The REM-11178 has lost connection to the Bus Solid Coupler.
Connection Guidelines • Make sure that devices you connect to the REM-11178 are compatible with the module specifications. • Push the wire into the terminal when using a solid wire or a stranded wire with a ferrule.
Removing Components Removing Spring Terminal Blocks Complete the following steps to remove a spring-terminal block from the REM-11178. Press the locking latch to release the spring-terminal block. Tilt the block toward the center of the module. Remove the connector from the module.
NI corporate headquarters is located at 11500 North Mopac Expressway, Austin, Texas, 78759-3504. NI also has offices located around the world. For telephone support in the United States, create your service request at ni.com/support or dial 1 866 ASK MYNI (275 6964). For 12 | ni.com | REM-11178 Getting Started Guide...