Basic Settings; Calibration - LINOVISION IOT-S500 Series User Manual

Table of Contents

Advertisement

Session Key
Spread Factor
Confirmed Mode
Rejoin Mode
ADR Mode
Support
Frequency
Channel

4.2 Basic Settings

Parameters
Reporting Interval
Change Password

4.3 Calibration

Parameters
Select spread factor from SF7 to SF12.
If the sensor does not receive ACK package from
network server, it will resend data 3 times most.
Sensor will send specific mounts of LoRaMAC
packages to check connection status regularly. If no
reply after specific packages, the sensor will re-join.
Allow network server to adjust datarate of the
sensor.
LoRaWAN region.
Enable or disable LoRa channels.
If frequency is one of CN470/AU915/US915, you can
enter the index of the channel that you want to
enable in the input box, making them separated by
commas.
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and
Channel 60
All: Enabling all channels
Null: Indicates that all channels are disabled
Description
Interval of sending sensor data. Default: 10min.
Change the password of logging Toolbox (Windows) and parameter
modify(mobile APP).
Description
After saving the calibration value, the sensor will add the
calibration value to raw value and send the final value.
52613230313823
SF10-DR2
Disabled
Enabled, 8 packages
Enabled
EU868
AU915