03
67 (Temperature)
04
68(Moisture)
7d(Conductivity)
05
IOT-S500SWL
Channel
01
75(Battery Level)
03
77 (Water Level)
IOT-S500UDL-W050
Channel
01
75(Battery Level)
03
82 (Distance)
6.3 Downlink Commands
IOT-S500 sensors support downlink commands to configure the device. Application port is 85 by
default.
Channel
ff
03(Set Reporting Interval)
Appendix
Default LoRaWAN Parameters
DevEUI
AppEUI
10 01
f0 00
Type
Data Example
02 00
Type
Data Example
1e 00
Type
24E124 + 2
to 11
nd
e.g. SN = 61 26 A1 01 84 96 00 41
Then Device EUI = 24E124126A101849
24E124C0002A0001
10 01 => 01 10 = 272
Temp=272*0.1=27.2°C
71
Hum=113*0.5=56.5%
f0 00 => 00 f0 =240 µs/cm
64
Battery level =100%
02 00=>00 02=2cm
64
Battery level =100%
1e 00=>00 1e=30mm
Data Example
b0 04
digits of SN
th
71=>113
Description
64=>100
Description
64=>100
Description
b0 04 => 04 b0 = 1200s