Lexing LX-180GS12 Instruction

Microwave sensor lamp

Advertisement

Quick Links

LX-180GS12 Microwave Sensor Lamp Instruction
Packing list in
Quantity
Microwave Sensor Lamp
1X
2X
Φ6
Plastic Expansion
2X
3x30 Screw
1X
Instruction
IP 20

Name of each part

Mounting holes
Microwave sensor
Mounting holes
Lamps and lanterns base

Specifications

Power source: 100-240V/AC
Power frequency: 50/60Hz
Rated load: 10.5-12W Max.
HF system: 5.8GHz CW electric wave, ISM wave band
Transmission power: <0.2mW
Time setting: 15sec±3sec/1min±10sec/
3min±30sec/10min±1min (adjustable)
Light-control: 10LUX-50LUX-200LUX-2000LUX (adjustable)

Summary

This is a microwave sensor switches controlled LED lights,the microwave sensor was
built into the light ,it has 72pcs high brightness LEDs inside ,with total power of 10.5-12
watts. We adopt this sensitive advanced sensor switchs in lighting control, enabling the
light to turn on automatically when one comes , automatically turn off when one goes out.
In addition to the widely usage in the aisle stairs ,living room and bedrooms , it also can
be installed in the bathroom.
Use high quality White frosted glass chimney.Strengthen the
flexible refraction of light.And its function of anti-ultraviolet
makes the shade not easy to turn yellow and be broken.
Mounting holes
Threading hole
Mounting holes
DIP Switch
72mm
70mm
Unscrew
PC lampshape
Detection range: 2m-6m-14m(diameter) (adjustable)
Detection angle: 360°
Standby power: approx.0.5W
Installation height: 2.5-3.5m (ceiling mount)
Lamp part
LED quantity: 72PCS
LED specifications: 2835
147mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LX-180GS12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Lexing LX-180GS12

  • Page 1 LX-180GS12 Microwave Sensor Lamp Instruction 72mm 70mm 147mm Summary Packing list in Quantity This is a microwave sensor switches controlled LED lights,the microwave sensor was Microwave Sensor Lamp built into the light ,it has 72pcs high brightness LEDs inside ,with total power of 10.5-12 watts.
  • Page 2 Sensor information 360º Max:7m Max:7m Min:1m Min:1m Height of installation2.5~3.5M Sensing distance adjustment range Sensing angle adjustment range Function Setting manner one:DIP switch As below shown, by S1,S2 to set the detection range, S3,S4,S5 the delay time, S6,S7,S8 the light-control value.
  • Page 3 (2)Time setting It can be defined from 12 seconds to 11minute. Time setting Any movement detected before this time 10min±1min elapse will re-start timer. 3min±30sec recommended to select the shortest time for 1min±10sec adjusting detection range 15sec±3sec performing the walk test. To set the switch to ON is “1”, to OFF is “0”.
  • Page 4 Fault and the solution Fault Failure cause Solution Light-illumination is set incorrectly. Adjust the setting of the load. The load fails to work. The load is broken. Change the load. Turn the power on. The power is off. Check the settings of the The load works all the time.

Table of Contents