Care & Cleaning - Frigidaire FRTB7B4EMB1 Use And Care Manual

Frigidaire frtb7b4emb1: user guide
Hide thumbs Also See for FRTB7B4EMB1:
Table of Contents

Advertisement

PROPER CLEANING OF BEVERAGE CENTER
DISPENSING SYSTEM
Your beverage center's beverage dispensing system needs
regular cleaning and sterilization in order to continue serving
draft beer with its pure brewery flavor. It is recommended that
the delivery lines be cleaned weekly and the entire delivery
system cleaned before a new keg is attached. This is a
relatively simple task. You will need the following parts to clean
your unit's dispensing system. These parts are available at any
draft beer dispensing equipment supplier or call Electrolux
Consumer Services at 1-800-944-9044 for kit CK-1100, part #
5304443671.
(A) 1 Quart Plastic Cleaning Bottle
(B) Low Profile Hand Pump
(C) Solid Brass Faucet Cleaning Attachment
(D) 4 oz. Bottle of Cleaning Solution
(E) Faucet Wrench
(F) Faucet Cleaning Brush
Mix one gallon of warm water with one ounce of the
cleaning solution in a bucket.
Remove the bottle cap and fill the bottle with the solution.
Replace the cap. Do not discard the remaining solution.
Before removing the delivery line from the tap or from
the coupler, make sure the remaining beverage in the
delivery line is blown out. This can be done by quickly
opening and closing the regulator outlet valve.
Remove the coupler from keg by rotating it
counterclockwise.
Remove the braided hose (gas line) from the coupler.
Make sure the canister valve and regulator shut-off valve
is shut off before removing the hose.
Remove the faucet from the shank assembly by turning
the threaded stainless steel collar clockwise using a
faucet wrench.
Disassemble the faucet parts and place in the cleaning
solution bucket.
Attach the brass attachment on the end of the cleaning
hose to the faucet shank assembly by turning the stainless
steel collar counterclockwise. Tighten the collar slightly.
If the coupler has a shutoff, make sure it is in the open
position.
Place the keg coupler in the cleaning solution bucket and
pump the cleaning solution through the beer line.
Clean the faucet parts and keg coupler thoroughly using
the faucet cleaning brush. Also, use the faucet cleaning
brush to clean around the shank and coupling.
Rinse all the parts with cool fresh water and reassemble
the faucet.
Detach the cleaning solution bottle from the faucet shank
by turning the threaded stainless steel collar clockwise.
Rinse the bottle with cool fresh water.
Fill the bottle with fresh water and re-attach it to the faucet
shank assembly. Pump the water through the delivery
line (clear hose). Make sure the end of the line is in a
bucket to collect rinse water.
Disconnect the cleaner and reinstall the faucet to the
shank by turning the collar counterclockwise using a
CARE & CLEANING (continued)
N O T E
N O T E
N O T E
N O T E
N O T E
Read and follow the instructions that come with the cleaning
kit before cleaning your beverage cooler.
NEVER CLEAN CONDENSER (SOME MODELS)
If your beverage center is equipped with a Never Clean
condenser, there's no need to clean the condenser under
normal operating conditions. If the beverage center is operated
under particularly dusty or greasy conditions, or if there is
significant pet traffic in your home, it may be necessary to
periodically clean the condenser for maximum efficiency.
18
faucet wrench and tightening it slightly. DO NOT over
tighten the collar.
Reattach the braided hose (gas line) to the keg coupler
and open both the canister valve and regulator shut-off
valve.
Reattach the keg coupler to the keg. Refer to Coupler to
Keg Installation procedures.
Remove the sump and drip tray from the door and clean
thoroughly. Refer to Cleaning and Maintenance Guide.
Reinstall the sump and drip tray to the door. Refer to Sump
and Drip Tray Assembly Installation procedures.
Defrost Water Pan (some models)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Beverage center ii

Table of Contents