Ro Specifications - Hague WaterMax H3500 Owner's Manual And Installation Manual

Table of Contents

Advertisement

RO Specifications

Model Part #
Membrane
Production Rates
Gallons per day
2
Liters per day
2
WQA gpd
3
WQA lpd
3
Water Pressure
(Min-Max) psi (kPa)
Water Temperature
(Min-Max) Deg. F (Deg. C)
Chlorine Tolerance (ppm)
Max. Hardness (Gr. pg)
Max. Iron (ppm)
Max. Mang. (ppm)
pH Limit
Max. TDS Limit (ppm)
Hydrogen Sulfide (ppm)
Max. Turbidity (NTU)
TDS Rejection
Typical @ 60 psi (414 kPa)
WQA @ 50 psi (345 kPa)
Storage–Gal. (L)
Water Supply
Treatment Stages
Prefiltration
PCF
Postfilter
Height–inches (cm)
Width–inches (cm)
Depth–inches (cm)
Weight–lb (kg)
Efficiency Rating
5
Recovery Rating
6
H6000 and H3500 are certified by WQA to NSF/ANSI Standard 58 for specific
1
performance claims as verified and substantiated by the test data. These are the only
units certified by WQA.
Product output is measured to atmosphere with feed water of 77°F (25°C), 60 psi
2
(414 kPa) and 360 ppm TDS.
WQA production is measured against a pressure tank @ 5 psi (34 kPa) backpressure,
3
77°F (25°C), 50 psi (345 kPa) and 750 mg/L ± 40 mg/L TDS,
1 NTU turbidity 7.5 ± 0.5 pH, 1 US/cm.
LC100P uses dual function prefilter for chlorine taste and odor removal.
4
Note: Actual production rates may vary depending on water temperature, pressure, TDS
level and membrane type.
WaterMax RO Owner's Manual
H6000
1
3140
TFC
N/A
N/A
19
72
40–100
(276–689)
40–113
(4.4–45)
0
10
< 0.1
< 0.05
5.0–9.0
2000
0.00
1.0
N/A
WQA=90.1%
3 (11.35)
Municipal, Well, Non-
Municipal, Well, Non-Chlorinated
Chlorinated
5
5 Micron
Sediment, GAC
Standard
GAC
16.75 (42.5)
14.5 (36.8)
7 (17.8)
35 (15.9)
8.2%
16.6%
H3500
1
2141
TFC
N/A
N/A
29
109.77
40–100
(276–689)
40–113
(4.4–45)
0
10
< 0.1
< 0.05
5.0–9.0
2000
0.00
1.0
N/A
WQA=90.1%
3 (11.35)
5
1 Micron
Sediment/ Carbon Block
Standard
GAC
16.75 (42.5)
14.5 (36.8)
7 (17.8)
35 (15.9)
13.7%
27.2%
Efficiency Rating means the percentage of the influent water to the system that is
5
available to the user as reverse osmosis treated water under operating conditions that
approximate typical daily usage.
Recovery Rating means the percentage of the influent water to the membrane portion of
6
the system that is available to the user as reverse osmosis treated water when the
system is operating without a storage tank or when the storage tank is bypassed.
Storage tank not included. Can use any size storage tank.
7
This reverse osmosis system contains a replaceable component critical to the efficiency of
the system. Replacement of the reverse osmosis component should be with one of
identical specifications, as defined by the manufacturer, to assure the same efficiency and
contaminant reduction performance.
9/2020
LC100P
N/A
TFC
100
378
N/A
N/A
40–100
(276–689)
40–113
(4.4–45)
0
10
< 0.1
< 0.05
5.0–9.0
2000
0.00
1.0
97%–98%
N/A
Optional
7
Municipal, Well, Non-Chlorinated
4
4
5 Micron,
20-inch
Sediment, GAC
N/A
GAC
28.75 (73)
14.5 (36.8)
7 (17.8)
40 (18.1)
N/A
N/A
41