5.1

Configuring WiN5200 Basic Parameters

Note
The WiN5200 may be pre-configured in the lab before being sent for installation at the customer's site.
In this case, this section can be skipped.
After completing the installation process, the basic parameters must be configured to ensure
that the unit operates correctly and can communicate with the base station. Once the basic
parameters have been configured, additional parameters can be remotely configured via the
wireless link
1. connect to the IP address 192.168.254.251 with the web browser through the Ethernet
port
2. In the Login window, enter username=vendor, password=vendorpass.
Figure 5-1: Login Screen
3. Check the WiN5000/5200 is configured to work in the correct frequency. To do so, choose
the "CONFIG" tab and then choose showScanner. Press the "CALL" button. The
command lists the channels (frequency and bandwidth pairs) the WiN5000/5200s scan in
order to communicate with the base station. The channel values are set at the factory.
Figure 5-2: showScanner screen
WiN5200