SIREMOBIL Compact
System Manual
Installation Instructions
CODONICS Printer EP 1660
Print No.: SPR2-130.814.01.01.02
Replaces: n.a.
SP
© Sie mens AG 2001
The reproduction, transmission or
use of this document or its contents
is not permitted without express
written authority. Offenders will be
liable for damages. All rights,
including rights created by patent
grant or registration of a utility
model
_or_ design,_are_
reserved.
English
Doc. Gen. Date: 03.01

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIREMOBIL Compact CODONICS EP 1660

  • Page 1 SIREMOBIL Compact System Manual Installation Instructions CODONICS Printer EP 1660 © Sie mens AG 2001 The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model...
  • Page 2 0 - 2 Revision Chapter Page Revision SIREMOBIL Compact SPR2-130.814.01 Page 2 of 4 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 3: Table Of Contents

    Film segmentation ........3 - 2 Enabling the Framegrabber Service Modes ..... 3 - 3 Siemens AG SPR2-130.814.01...
  • Page 4 Final work........3 - 9 SIREMOBIL Compact SPR2-130.814.01 Page 4 of 4 Siemens AG System Manual Rev. 01 03.01...
  • Page 5: Safety Notes

    99 00 440 RE999 Required tools • Tool kit • 1 set of Allen keys • 1 set of torque screwdrivers Siemens AG SPR2-130.814.01 Page 1 of 2 SIREMOBIL C Medical Solutions Rev. 01 03.01 TD PS 24 System Manual...
  • Page 6 1 - 2 General This page intentionally left blank. SIREMOBIL C SPR2-130.814.01 Page 2 of 2 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 7: With Prepared Monitor Trolley (New Delivery)

    Turn the two transport locks into vertical position and pull out in vertical position (Fig. 1). Keep the two transport locks. If the printer needs to be replaced NOTICE or sent in, the transport locks must be re-inserted. Siemens AG SPR2-130.814.01 Page 1 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 8: Unpacking The Framegrabber

    3). • The fan and the connections of the framegrabber point to the rear. SIREMOBIL Compact SPR2-130.814.01 Page 2 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 9: Installation Of The Printer In The Monitor Trolley

    • Unscrew the two screws (1/Fig. 5) from the angle bracket (2/Fig. 5). • Attach the power chain (3/Fig. 5) to the bracket (2/Fig. 5) with the two screws (1/Fig. 5). Siemens AG SPR2-130.814.01 Page 3 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 10: Wiring The Hand-Held Control Unit

    Insert the control cable in the printer socket and lock mechanically (3/Fig. 6). • Insert the power supply for the fans in the socket (4/Fig. 6). SIREMOBIL Compact SPR2-130.814.01 Page 4 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 11: Wiring The Framegrabber

    Switch on power to the framegrabber (12/Fig. 6). • Load the film cassette with film screens and insert in the printer. • Additional steps: see Startup section. Siemens AG SPR2-130.814.01 Page 5 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 12: Installation When Upgrading In The Field

    Manually change the fuse value of the F5 fuse to 6.25 AT in the wiring diagram. • Enter the remark "Condonics printer installed" together with the date and your initials. SIREMOBIL Compact SPR2-130.814.01 Page 6 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 13: Installation Of The Guide Rails, Including The Fan, And The Installation Plate Of The Framegrabber In The Monitor Trolley

    Lock washers are not required, since self-locking nuts are attached to the mounting plate. • The front screw holes can be accessed by pulling out the rails (Fig. 9). Siemens AG SPR2-130.814.01 Page 7 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 14: Unpacking The Printer

    Open the packaging of the framegrabber from the top. • Remove the framegrabber and the hand-held control unit. • Remove the plastic bag. SIREMOBIL Compact SPR2-130.814.01 Page 8 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 15: Installing The Framegrabber In The Monitor Trolley

    Insert the framegrabber from the front in the fixing bracket and secure laterally to the fixing bracket with the lock washers and knurled screws supplied(1/Fig. 12). • The fan and the connections of the framegrabber point to the rear. Siemens AG SPR2-130.814.01 Page 9 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 16: Installation Of The Printer In The Monitor Trolley

    Unscrew the two screws (1/Fig. 14) from the angle bracket (2/Fig. 14). • Attach the power chain (3/Fig. 14) to the bracket (2/Fig. 14) with the two screws (1/Fig. 14). SIREMOBIL Compact SPR2-130.814.01 Page 10 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 17: Wiring The Hand-Held Control Unit

    Reattach the cover (1/Fig. 16). • Plug in the two connectors of the fan wires to the corresponding connectors (2/Fig. 16). • Lock the fan wires with the cable holders (3/Fig. 16). Siemens AG SPR2-130.814.01 Page 11 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 18: Wiring The Framegrabber

    Connect the BNC connector to the looped-through output of the video recorder or vidoeprinter and lock. • The 75-ohm terminator on the video recorder or video printer must be disconnected or unplugged. SIREMOBIL Compact SPR2-130.814.01 Page 12 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 19: Power Switch

    Screw the protective conductor onto the new rear cover. • If the new rear cover does not contain cable holders, unscrew the cable holders of the old rear cover and mount on new rear cover. Siemens AG SPR2-130.814.01 Page 13 of 14 SIREMOBIL Compact Medical Solutions Rev.01_V 03.01...
  • Page 20 2 - 14 Installation This page intentionally left blank. SIREMOBIL Compact SPR2-130.814.01 Page 14 of 14 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 21: Inquiry Regarding Customer Requirements

    The following film segmentations can be programmed on the framegrabber / printer: Full format, 2-on-1, 3-on-1, 4-on-1 and 6-on-1 segmentation. • Enquire with the customer as to the preferred film segmentation and make a note of it. Siemens AG SPR2-130.814.01 Page 1 of 10 SIREMOBIL Compact Medical Solutions Rev.
  • Page 22: Startup Of The Printer / Framegrabber

    Selected menus can be closed again with the "Erase/Cancel" key. Changes of values/ parameters previously confirmed by "OK/Enter" are taken over. • Press the "Menu" key to return to the main menu. SIREMOBIL Compact SPR2-130.814.01 Page 2 of 10 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 23: Enabling The Framegrabber Service Modes

    Select the "Auto Date/Time" menu line with the cursor key " " or " " and press the "OK/Enter" key. • Press the "Menu" key to select the main menu again. Siemens AG SPR2-130.814.01 Page 3 of 10 SIREMOBIL Compact Medical Solutions Rev. 01 03.01...
  • Page 24: Memoskop Video Singals At Hardcopy Output

    - Then click the "Put to Memoskop" button in the main menu of the service program. The SMPTE test image is displayed on both monitors. • If a MEMOSKOP keyboard is available, switch on the text overlay. SIREMOBIL Compact SPR2-130.814.01 Page 4 of 10 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 25 " on the control panel of the framegrabber and press the "OK/Enter" key. • ↑ ↓ Select the line "SIEMENS" with the cursor key " " or " " and press the "OK/Enter" key. • 4 selection menus are available:...
  • Page 26: Automatic Sizing With Existing 50/60 Hz Monitors

    " or " " on the control panel of the framegrabber and press the "OK/Enter" key. • ↑ ↓ Select the line "SIEMENS" with the cursor key " " or " " and press the "OK/Enter" key. • ↑ ↓...
  • Page 27: Testing The Image Quality

    0.34 0.41 0.48 n.a. 0.22 0.28 0.34 n.a. 100% 0.16 0.24 Table 1: Reference values with programmed positive image display Siemens AG SPR2-130.814.01 Page 7 of 10 SIREMOBIL Compact Medical Solutions Rev. 01 03.01 TD PS 24 System Manual...
  • Page 28 2.31 2.56 2.81 n.a. 2.50 2.77 3.05 n.a. 100% 2.60 2.90 3.20 Table 2: Reference values with programmed negative image display SIREMOBIL Compact SPR2-130.814.01 Page 8 of 10 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...
  • Page 29: Final Work

    • Carry out the protective conductor test in accordance with ARTD-002.731.17. The protective conductor resistance must not exceed 0.2 Ohms. • Hand over the operating instructions to the customer. Siemens AG SPR2-130.814.01 Page 9 of 10 SIREMOBIL Compact Medical Solutions Rev.
  • Page 30 3 - 10 Commissioning This page intentionally left blank. SIREMOBIL Compact SPR2-130.814.01 Page 10 of 10 Siemens AG System Manual Rev. 01 03.01 TD PS 24 Medical Solutions...