Main Unit; Maintenance; Replacing The Fuse - X-Tronic DFX-300 Instructions Manual

Table of Contents

Advertisement

MAIN UNIT

• Keep the main unit turned off and unplugged when not in use.
• Use a damp cloth to clean the unit as needed.
FIBER FILTERS
• This unit uses 4 high efficiency fiber filters. These filters are found
attached to the unit covers on the top and back and under the fans
inside the unit.
• The fiber filters can be vacuumed on a regular basis to remove
dust.
• If the fiber filters require more than vacuuming will provide, they
can be removed and washed with warm water. They will need to
dry fully before being placed back in the unit.

REPLACING THE FUSE

Fuse
Compartment
1. Unplug the power cord from the outlet.
2. Remove the fuse compartment by pressing a flat head screwdriver
into the divot just inside the power socket under the fuse
compartment.
3. The fuse that is in use will be in the fuse clip, the extra fuse is
below it. If the fuse is damaged, replace it with the new fuse.
4. Insert the fuse compartment back into the unit.

MAINTENANCE

Compartment
- 7 -
Fuse Clip
Extra Fuse
Fuse