AUSTRALIAN REQUIREMENTS:

To be installed on a firm, level surface in accordance with AS 5601 / AG 601, local authority, gas, electricity, and any
other relevant statutory regulations. The Australian orifice size and manifold pressures are listed below for the SR42 and
SR62 fryers.
Model
Gas Type
SR62GN
Nat
SR62GP
Prop
SR42GN
Nat
SR42GP
Prop
CE UNITS ONLY:
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity/Color, Burner Markings
and Pilot Markings are listed in the table below:
NOMINAL
HEAT INPUT-
MODEL*
GAS TYPE
Qn
(kW)
SR62 GM
37.5
SR52 GM
30
SR42 GM
26
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
NON-CE UNITS ONLY:
Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Pressures and Adjustments, Orifice Quantity, and Pilot Markings are
listed in the table below:
NOMINAL
HEAT INPUT-
MODEL*
SR62 GM
SR52 GM
SR42 GM
*SR prefix- Super Runner Series
*GM suffix- gas millivolt system with no electrical supply connections required
NOTE: Outlet gas pressure must be adjusted strictly within the above
requirements 5 to 10 minutes after the appliance is operating.
1.4
Connection to the Gas Supply Line
NOTE: The gas supply (service) line must be the same size or greater
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company
or supplier, or your local contractor for minimum supply line
requirements.
SUPER RUNNER SERIES GAS FRYERS
CHAPTER 1: INSTALLATION INSTRUCTIONS
Orifice Size
Manifold Pressure KPa
2.53 mm
0.9 KPa
1.6 mm
2.4 KPa
2.8 mm
0.87 KPa
1.65 mm
2.5 KPa
MANIFOLD GAS PRESSURE
ORIFICE
SIZE (MM)
G20
2.40
G25
2.40
G31
1.51
G20
2.40
G25
2.40
G31
1.51
G20
2.40
G25
2.40
G31
1.51
ORIFICE
GAS TYPE
Qn
SIZE (MM)
(BTU)
NAT
2.53(#39)
150
LP
1.51(#53)
NAT
2.53(#39)
120
LP
1.51(#53)
NAT
2.80(#35)
105
LP
1.70(#51)
Manifold Pressure Inches WC
3.6"
9.6"
3.5"
10"
MBAR
INCH W.C.
12,0
4,8
17,5
7,0
22,0
8,8
12,0
4,8
17,5
7,0
22,0
8,8
12,0
4,8
17,5
7,0
22,0
8,8
MANIFOLD GAS
ORIFICE
PRESSURE
QUANTITY
(INCH W.C.)
4
11
4
11
4
11
1-3
ORIFICE
BURNER
QTY/ COLOR
MARKING
MARKING
5/BLUE
Blue
5/BLUE
Blue
5/RED
Red
4/BLUE
Blue
4/BLUE
Blue
4/RED
Red
3/BLUE
Blue
3/BLUE
Blue
3/RED
Red
PILOT
MARKING
5
26N
5
16LP
4
26N
4
16LP
3
26N
3
16LP
Propane Applications;
Proper Regulator Must Be Installed
PILOT
26N
26N
16LP
26N
26N
16LP
26N
26N
16LP