Advertisement

Quick Links

CTE9
Extractor
Installation, use and maintenance
www.cda.eu

Advertisement

Table of Contents
loading

Summary of Contents for CDA CTE9

  • Page 1 CTE9 Extractor Installation, use and maintenance www.cda.eu...
  • Page 2: Table Of Contents

    Contents: Important Important information Using your extractor Care and maintenance Troubleshooting 10 - 13 Installation Installation - height Installation - preparation and ducting Installation - mounting the extractor Non-return flaps Mains electrical connection...
  • Page 3: Important

    Appliance information: Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with your appliance and to register your appliance for guarantee purposes. Appliance Model...
  • Page 4: Important Information

    safety (LVD) and Electromagnetic interference compatibility (EMC). IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EU DIRECTIVE 2012/19/EU. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services.
  • Page 5 Please note: • Under no circumstances should the extractor be connected to any gas ventilation system, flue system or hot air ducting system. • Do not vent the extractor into an attic or loft space. • Only house the extractor in rooms with adequate ventilation.
  • Page 6: Using Your Extractor

    Using your extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Controls A - Lamp switch B - Left speed switch C - Right speed switch Fig.
  • Page 7: Care And Maintenance

    To switch the lights on Slide open the canopy and activate the lamp switch (A). Fig. 1 shows the switch in the off position. To switch the lights off Simply close the sliding canopy. The lights will come back on when the canopy is re-opened.
  • Page 8 To ensure best performance of your extractor, you should replace the charcoal filters every four to six months, depending on use. The charcoal filters are an optional accessory. These are available from the CDA Sales team on 01949 862010 under code CHA35. To attach the charcoal filters: •...
  • Page 9: Troubleshooting

    4. If the extractor still extracts, then it’s possible both bulbs have gone. The bulbs are 3W E14 (SES) LEDs. Contact CDA Customer Care A: Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY T: 01949 862 012 F: 01949 862 003 E: customer.care@cda.eu...
  • Page 10: Installation - Height

    - 65cm must exceed 650mm. CDA Gas hob - 75cm When the extractor is to be installed above a CDA gas hob, the minimum distance between the hob and extractor must exceed 750mm. Fig. 3 If the instructions provided with your gas hob state that the required distance between the hob and extractor must be greater than 750mm, then that is the distance that should be observed;...
  • Page 11: Installation - Preparation And Ducting

    Installation - preparation and ducting The metal casing of this appliance has been coated with a film to protect it during transport and storage. This should be removed during installation and any adhesive removed by using a non- abrasive stainless steel cleaner. Always follow the instructions given with the cleaner being used.
  • Page 12: Installation - Mounting The Extractor

    Installation - mounting the extractor This extractor is designed to be installed within a bridging unit and is not suitable for direct wall mounting. It is intended to be held in place within the unit by four screws through a support shelf. The positions of these screws, and the ducting outlet cutout, are shown on a template supplied with the appliance.
  • Page 13 Using the template supplied, drill out the mounting screw holes, the ducting outlet and a route for the mains lead, if required. Attach the ducting adapter, supplied with the appliance, to the extractor. Remove the grease filters to stop them being damaged. Attach the ducting to the extractor and then fit the extractor into the unit, routing the ducting first.
  • Page 14: Non-Return Flaps

    Non-return flaps Where possible, the non-return flaps should be used. These attach to the ducting apator and help to prevent any debris from falling into the motor. Please note: these may cause a clicking or tapping noise when returning to their position after use, or even when the extractor is not in use (this is due to the air pressure in the ducting channel).
  • Page 15: Mains Electrical Connection

    Mains electrical connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C.
  • Page 16 Note: Use a 3A Fuse. Assembly and electrical connection should be carried out by specialised personnel. The isolation switch and fuse for this appliance should be easily accessible after installation is complete. Electrical information Mains electrical voltage: 230-240Vac Total rated power consumption: 131W...
  • Page 17 NOTES: E & O E. All instructions, dimensions and illustrations are provided for guidance only. CDA reserve the right to change specifications without prior notice.
  • Page 18 For more information please contact: The Sales Department on 01949 862 010 or email sales@cda.eu Customer Care Department. The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY 01949 862 012 F: 01949 862 003 E: customer.care@cda.eu www.cda.eu...