Monitor Screen - Toshiba RBC-AMSU51 -ES Installation Manual

Wired remote controller
Table of Contents

Advertisement

 Monitor screen
Check the current usage status.
Room A
24
Cool
Mode
Monitor
Set temp.
(1)
Control temp.
(2)
Outdoor temp.
(3)
Filter remaining hour
(4)
Total running hour
(5)
Return
NOTE
Total running hour
• The Total running hour is recorded on the remote controller.
• The time is not recorded during Self cleaning operation or fan operation.
Outdoor temp.
• Displays the temperature around the vent of the outdoor unit.
• The displayed temperature may differ from the actual outdoor temperature.
Others
• The Header status appears during group connection.
• The screen returns to the previous display if no operation is performed for 60 seconds.
• When using a Remote sensor or a sensor with Wired remote controller, the setting temperature may not be controlled
accurately due to a difference between the temperature of their sensor and room temperature that can arise due to
radiant heat effects of the wall etc.
12:00
Fan Speed
24°C
24°C
35°C
2500
10480
1
Push [
MONITOR] button.
The monitor screen appears.
2
Push [
CANCEL] button to return.
(1) Displays the set temperature.
(2) Displays the temperature measured by the indoor
temperature sensor of the indoor unit.
If the sensor is set to that of the remote controller,
the temperature measured by the remote sensor is
displayed.
(3) Displays the temperature around the vent of the
outdoor unit.
(4) Displays the remaining time until the filter sign lights
up.
(5) Displays the accumulated operating time.
– 11 –
Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rbc-amsu51 -en

Table of Contents