 Monitor screen
Check the current usage status.
Room A
24
Cool
Mode
Monitor
Set temp.
(1)
(2)
Control temp.
Outdoor temp.
(3)
Filter remaining hour
(4)
Total running hour
(5)
Return
NOTE
Total running hour
• The Total running hour is recorded on the remote controller.
• The time is not recorded during Self cleaning operation or fan operation.
Outdoor temp.
• Displays the temperature around the vent of the outdoor unit.
• The displayed temperature may differ from the actual outdoor temperature.
Filter remaining hour
• The filter remaining hour is not displayed when the filter cleaning timer of the indoor unit is not set.
12:00
Fan Speed
24°C
24°C
35°C
2500
10480
1
Push [
MONITOR] button.
The monitor screen appears.
2
Push [
CANCEL] button to return.
(1) Displays the set temperature.
(2) Displays the temperature measured by the room
temperature sensor of the indoor unit.
If the sensor is set to that of the remote controller,
the temperature measured by the remote sensor is
displayed.
(3) Displays the temperature around the vent of the
outdoor unit.
(4) Displays the remaining time until the filter sign lights
up.
(5) Displays the accumulated operating time.
– 10 –