30" GAS RANGE INSTALLATION INSTRUCTIONS

Air Shutter-Broil Burner

10
The approximate flame length from the burner is 1 inch
(distinct inner cone of blue flame).
To determine if the broil burner flame is proper, set the
oven to broil.
If flame is yellow in color, increase air shutter opening
size (see "2" in Figure 8 ). If the entire flame is blue,
reduce the air shutter opening size.
To adjust, loosen lock screw (see "3" in Figure 8),
reposition air shutter, and tighten lock screw.
Lock
3
Screw
2
Figure 8
Make sure range is level
11
Level the range by placing a level horizontally on an
oven rack. Check diagonally from front to back, then
level the range by adjusting the leveling legs.
After installation is completed, make
12
sure all controls are left in the OFF
position.
LP/Propane Gas Conversion
This appliance can be used with Natural gas or LP/
Propane gas. It is shipped from the factory for use
with natural gas.
If you wish to convert your range for use with LP/
Propane gas, use the supplied fixed orifices located
in a bag containing the literature marked "FOR LP/
PROPANE GAS CONVERSION." Follow the instructions
packaged with the orifices for surface, oven and broil
burners conversion.
The conversion must be performed by a qualified
service technician in accordance with the
manufacturer's instructions and all local codes and
requirements. Failure to follow these instructions
could result in serious injury or property damage.
The qualified agency performing this work assumes
responsibility for the conversion.
Failure to make the appropriate
conversion can result in serious personal injury and
property damage.
Oven Burner
Tube
Orifice
1
Hood
8

Care, Cleaning and Maintenance

Refer to the Use & Care Guide for cleaning
instructions.
If moving the range is necessary for cleaning or
maintenance, shut off gas supply. Disconnect the
gas and electrical supply. If gas or electrical supply is
inaccessible, lift the unit slightly at the front and pull
out away from the wall.
Pull only as far as necessary to disconnect the gas and
electrical supply. Finish moving the unit for servicing
and cleaning. Reinstall in reverse order making sure to
level the range and check gas connections for leaks.

Before You Call for Service

Read the Before You Call for Service Checklist and
operating instructions in your Use and Care Guide.
It may save you time and expense. The list includes
common occurrences that are not the result of
defective workmanship or materials in this appliance.

Serial Plate Information