5 TECHNICAL SPECIFICATION

5.1 Technical specifications

Quantity
t
U
in
U
out
F
Time settings
Channel-specific lubrication cycle can be set within 1 min - 999 h 59 min.
Channel-specific maximum pressurization time can be set within 0 s - 9999 s.
All time settings are password-protected.
Power failure protection
The set values and configuration settings stored in the EEPROM-memory do not require a
back-up battery protection. Program status and lubrication history data are protected by a back-
up battery.
14402BEN.doc
Range
0...+60
230 ±15%, 50/60
115 ±15%, 50/60
24
6
600 x 600 x 210
(w x h x d)
IP55
SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
Unit
Description
°C
operation temperature
V AC, Hz
Power input, 250 W max.
V AC, Hz
Voltage area selection within the power supply
Voltage range preset at factory and indicated
in the center name plate.
V DC
Control voltage, regulated 10 A max.
The internal power supply for controlling the
system.
A
Automatic fuse
mm
Steel enclosure
Protection classification
18 (19)