Lubrication Cycle Counter - SAFEMATIC ST-1440 Manual

Safegrease, safeoil, multilube control center
Table of Contents

Advertisement

Switch control
in the pressure switch channel the pump stops when the pressure switch is closed and re-
starts when the switch is re-opened
in the pressure transmitter channel the pump is stopped when pressure exceeds the set
high limit and is re-started when pressure goes below the high limit value
Forced control
pump operates on forced control without any pressure control
Pumping time
Pumping time always starts at zero status, when pump is started.
When switch control is being used, time value is not reset, although pressure control unit
stops and starts the pump

3.4 Lubrication cycle counter

Channel lubrication cycle counter is displayed by selecting Page - Othr - Cntr at the basic
display.
CH12 SG2 Machine 1
lub. counter 00015
cleared
Chnl
Figure 6.
Display lines
Note
The first line indicates the selected channel
number (CH12)
operation mode (SG2)
name (Machine 1)
The second line indicates the selected channel
lubrication cycle count (lub. counter 00015)
The third line indicates the selected channel
the last date when the counter was cleared (cleared 14.05.97)
The fourth line indicates
the function key texts
14402BEN.doc
14.05.97
----
Clr Esc
Lubrication cycle counter display
The texts in brackets are sample display texts.
SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
9 (19)
12.11.2004 Rev. 2B

Advertisement

Table of Contents
loading