SAFEMATIC ST-1440 Manual page 16

Safegrease, safeoil, multilube control center
Table of Contents

Advertisement

Fields to be set
Field and unit
Tc, h
Tc, min
P, s
Hp, bar
Lp, bar
Display lines
Note
The first line indicates the selected channel
number (CH12)
operation mode (SG2)
name (Machine 1)
The second line indicates the selected channel
set lubrication cycle (Tc=024h00min)
set maximum pressurization time (P=0230s)
The third line indicates the selected pressure transmitter channel
pressure high limit (Hp=120bar)
pressure low limit (Lp=050bar)
Note
The fourth line indicates
the function key texts
Display function keys
Key
OK
Esc
14402BEN.doc
Description
Lubrication cycle time, hours
Lubrication cycle time, minutes
Maximum pressurization time
High pressure limit on pressure transmitter channel
Low pressure limit on pressure transmitter channel
The texts in brackets are sample display texts.
For pressure switch channel, this line is blank.
Description
Accepts the entered value
Press key to accept the entered value. The cursor moves onto the next field.
Back to basic display
SAFEGREASE, SAFEOIL, MULTILUBE
ST-1440
15 (19)
12.11.2004 Rev. 2B