Argox ArgoxScan 9500 Manual page 114

Table of Contents

Advertisement

B - Beeper: Causes a beep to sound after an image is snapped.
0B No beep (default)
1B Sounds a beep when the image is captured, notifying the user
that the imager can be moved.
E - Exposure: This allows you to set the exposure time. Units are
127microseconds. For example, an exposure setting of 50
x .000127ms = 6.35ms esposure time. Exposure is used in Manual
Style only. (Default = 7874)
nE Range: 0 - 7874
G - Gain: This modifier boosts the signal and multiplies the pixel
value. The range is 1-8.
1G No gain (default)
2G Medium gain
4G Heavy gain
8G Maximum gain
D - Delta for Acceptance: This sets the allowable range for the
white value setting (see W - Target White Value). Delta is only
available when using Photo Style. (Default = 25)
nD Range: 0 - 255
L - LED State: Determines if the LEDs should be on or off, and
when.Ambient illumination (0L) is preferred for taking pictures of
color documents,such as ID cards, especially when the imager is in
a stand. LED illumination
(1L) is preferred when the imager is handheld. LED State is not
available when using Decoding Style.
0L LEDs off (default)
1L LEDs on
T - Wait for Trigger: Waits for a hardware trigger pull before
taking the image.
0T Takes image immediately (default)
1T Waits for a trigger pull, then takes the image
U - Update Tries: The maximum number of frames the imager
should take to reach the Delta for Acceptance. Update Tries is only
available when using
Photo Style. (Default = 6)
nU Range: 0 - 10
112 

Advertisement

Table of Contents
loading