Winter ready
Warning! Failure to protect your product against the winter can result in damage and the
warranty does not cover this.
In areas with a lot of frost, make sure to protect the pump, filter and dosage application
from freezing.
It is recommended to store the appliances in a warm and dry area.
The electrodes must be stored frost‐free, in KCl liquid.
De pvc‐tubes must be dried.
The white dosing hose in the dosing device must be replaced preventively every year. In
the event of hose breakage, the chemicals flow into the dosing pump with the risk of
irreparable damage to the dosing pump.
In general there are 5 mechanisms through which the dosing tube can break:
A. The tube is at the end of its life (with chemical compatibility) after 500/600 hours of
performance
B. Determination of incompatible products with the "Santoprene" material of the tube (PH
regulation with HCI)
C. Increase of chemicals. Bottle with cling and acid on the pumps / pumps mounted on the
vertical bus.
D. Backflow blocks of the pump or injection blocked by limestone (more often in
calcareous waters.
E. Empty dosing vessel, as a result of which the peristaltic pump keeps running and the
500/600 hours of running time can be reached very quickly.
Spring startup
If your unit was protected against the winter, use the following steps prior to restarting
your product for spring:
1.
Recalibrate the electrodes
2.
Verify that the check valves in the dosage nipple isn't stuck.
3.
Verify that there aren't any leaks when the unit is under pressure and when the
dosage pumps are on.
8